4 Trouble shooting
Reading front panel LED status
There are six two-colour LEDs on an active or passive front panel, with yellow/green
indicating a normal condition and red an abnormal condition.
The Indigo 2 CoolFlow LEDs
The following LED status indications may be seen:
LED
Colour
Notes
Front Fan
Unlit
Green
Red
Door open
Normal operation
Change the panel fan
PSU Fan
Unlit
Green
Red
Door closed and fan idle
Door open and fan operational
Change PSU fan
Upper PSU
Unlit
Green
Red
No upper PSU detected
Normal operation
Change upper PSU
Lower PSU
Unlit
Green
Red
No lower PSU detected
Normal operation
Change lower PSU
Temp
Green
Red
Normal operation
Internal temperature too high (approx 65
o
C)
Comms
Unlit
Flash amber
Press Device in Statesman mode for comms
status
If a PSU is not fitted, the corresponding LED will not illuminate unless the incorrect number
of PSUs are selected when it will flash red.
The Comms LED indicates external communication with the frame. On a passive panel this
will mean communication from the frame or an active control panel. On an active panel this
will be communication with Statesman via an RS422 link or via Ethernet.