Note:
It is possible to verify that the correct frame is being viewed by first recording the Hex
switch setting (second line in status list), this is the setting of the frame address switch.
Rotate this switch to something other than the number displayed. Refreshing the browser
will then reflect this change and verify that the correct frame is being communicated
with.
Status
The status page gives an overview of the frame and its power supplies. The information
that can be found here includes general information about the network attributes, frame
name and serial number etc plus more frame specific information like internal
temperature, fan status and PSU type. Further information is also given about the
individual power supplies.
Changing the IP Address
An Ethernet-enabled frame will need to have its IP address set upon installation. This is
made possible by setting the frame to act as a web server and then accessing an internal web
page. Any software upgrades can also be downloaded to the frame via this web page.
From this web page you are able then to change the IP address manually or automatically if
DHCP is available. A frame serial number may also be entered.
To reset the IP address, from the status page select the Network link. A new page will open
allowing entry of the required IP address and Netmask. Enter the new IP address and
Netmask information and select Change. Should the frame be connected to a DHCP running
network and a fixed IP address is not required, leave all the information blank and tick the
DHCP box before selecting ‘Change’.
Network Window
Once Change has been selected the Network screen will be replaced by a confirmation
screen. As instructed lever four must be returned to the up position and the front panel
power cycled. This can be achieved by either briefly interrupting the power to the frame or
if this is not convenient, removing the ribbon-cable connection to the front panel. Care must
be taken not to bend any pins in the cable connect as attempting to re-straighten any bent
pins is likely to result in their fracture.