DAILY FUELING & FIRING ROUTINE
Prior to opening fuel door, on the control panel located on the left side of the furnace remember to turn fan/light
switch to either off or light position. Next press load switch time delay and wait 20 seconds to allow smoke to
evacuate from furnace. Open the fuel door slowly and stand behind the door so that the door is between you and the
firebox. Failure to wait may cause an injury from a fire flare back.
Do not load the firebox more than seventy-five percent (75%) with wood. If additional fuel is added, you will not
maintain a hot enough burn and your efficiency rate will deteriorate. Only add enough wood to provide heat until the
next fueling time. Overfilling the firebox will cause the fire to smolder, create excessive creosote and result in more fuel
being consumed.
SAFETY
Never open firebox door without turning off the fan/light switch, pressing the load switch time delay button, and
waiting 20 seconds to allow the smoke to evacuate from the furnace. These buttons are located on the control panel.
They are designed to turn on the combustion blower to evacuate all smoke from unit. Failure to do so could result in
damage to furnace and personal injury.
Whenever the firebox door is to be opened, it should always be cracked slightly to allow oxygen to enter and burn off
any combustion gases that are present before fully opening. Failure to do this could result in sudden ignition of the
unburned gases when the door is opened.
A stove should never be filled with excess wood so that the flue gas exit is blocked or impeded in any way. Burning
wood generates carbon monoxide and if the flue gas exit is blocked the carbon monoxide can be forced into the area the
stove is heating and have fatal consequences.
Do not fill the unit higher than as stated below.
RS 7200E: 20
” (inches) from the bottom of the door opening.
STARTING DURING A PROLONGED POWER FAILURE
During a prolonged power failure, where no power is being sent to the furnace, do not load with new fuel or try to start
a new fire. It is recommended that you contact your local dealer or Greentech Manufacturing, Inc. to find out what size
of generator is needed to keep your furnace running. Once an approved generator is connected to the stove, the unit
may be started normally.
OPERATION
WARNING!!!
Risk of Fire: Do not operate with fuel loading and / or ash removal doors open. Do not store fuel or
other combustible materials within marked installation clearances. Inspect and clean flues and chimney regularly
CAUTION!!!
Hot Surfaces: Keep children away. Do not touch during operation.
CAUTION!!!
Do not start the unit during a prolonged power failure.
23