ALL INSTALLATIONS AND OPERATIONS MUST FOLLOW FEDERAL, PROVINCIAL, STATE, AND LOCAL CODES FOR WIRING,
PLUMBING AND INSTALLING CHIMNEY. ALL WORK MUST BE PERFORMED BY QUALIFIED PERSONNEL ONLY.
Chimneys
The size and height all depends on the unit you have purchased and where the unit will be located. Contact your local
dealer or Greentech Manufacturing, Inc. for chimney purchase information.
Adhere by local building codes and the National Fire Protection Association Rules
No’s
31,54 and 211.
It is required to use Selkirk Chimney Systems; brand type is UT (Ultra Temp or Galva Temp)
Selkirk Chimney Systems is a double insulated, stainless steel, Class A Chimney Systems that meets the
requirements of UL103 and ULC-S629 and complies with the Chapter 11 of NFPA 211, Standard for Chimneys,
Fireplaces, Vents and Solid Fuel Burning Appliances.
Chimney termination caps are required; installation of spark arresters may be needed in high fire risk areas.
Selkirk chimneys come in various lengths, spanning from eighteen (18) inches to forty-eight (48) inches. Install
each section of piping by placing male and female sections together then twisting them to lock sections
together. When installing your chimney piping, it is recommended by many chimney suppliers to brace every
eight feet. Also recommended by the chimney manufacturer, that the height of the piping does not exceed a
total of forty 40 ft.
When installing chimney, please refer to
manufacturer’s
recommendations and requirements for adequate
clearances.
Furnaces come standard with the Selkirk brand, 6
” a
nchor plate as well as an
18” chimney length.
Additional Chimney components and lengths are available from your local dealer or can be purchased direct
from Greentech Manufacturing Inc. (Toll Free 866-361-7355)
Do not attempt to fabricate your own adapters.
Do not mix Selkirk Chimney with other manufactured brands.
Do not use existing chimney that already connects to another appliance.
A major cause of chimney-related fires is failure to maintain required clearances (air spaces) to combustible
material. It is of the utmost importance that the chimney be installed only in accordance with the
manufacturers stated instructions. These instructions must be reviewed prior to installation of venting
components.
Inspections of chimneys need to be performed at least annually to ensure of any obstructions due to creosote
buildup. When necessary perform cleaning of chimney to prevent chimney fires.
CHIMNEY
WARNING!!!
This unit cannot be hooked to a chimney already serving another appliance.
CAUTION!!!
Hot Surfaces: Keep children away. Do not touch during operation.
WARNING!!!
Risk of Fire: Do not operate with fuel loading door, heat exchanger door or secondary combustion
door and/or ash removal doors open. Do not store fuel or other combustible materials within marked installation
clearances. Inspect and clean flues and chimney regularly.