Control Panel
The aqua stat powers the combustion blower to maintain the desired water temperature. The aqua stat is set at 160°F
at the factory, which means that combustion blower will run until the water in the jacket reaches 160°F. As the outside
air temperature drops as the season progresses into the winter the settings can be raised to a high of 180°F. The reason
the aqua stat is set lower is because it is not necessary to have a high temperature in the fall and spring. Therefore, the
stand by heat loss is reduced. Only qualified personal should be adjusting the temperature controls.
When filling firebox place the fan/light switch to light off position and press the red load switch time delay button.
Wait 20 seconds to allow the smoke to evacuate from the furnace before opening firebox door. For night filling the
fan/light switch can be in the light position while filling which will turn on the light above firebox door.
Caution
–
Never open firebox door before pushing load switch time delay and waiting 20 seconds for smoke to evacuate
from furnace before opening firebox door. Damage to furnace and personal injury may result.
CONTROL PANEL
AQUA STAT
FAN/LIGHT SWITCH
Controls the water
temperature inside the
water jacket. Factory
set at 160°F with 10°
differentials.
Controls both fan and
light. Ensure switch is in
the light position
before opening fuel
door. This shuts the fan
off and turns on light.
Always put the switch
in the fan position after
refueling.
LOAD SWITCH
Turns the combustion
blower on to allow
smoke to evacuate from
furnace for 100
seconds, then returns to
normal operation.