7
• The entity parameters of Detective Net are:
Uo = 3.7 V
Ui = 10 V
Io = 14.3 mA
Ii = 25 mA
Po = 8.7 mW
Pi = 62.5 mW
Co = 999 uF
Ci = 240 nF
Lo = 173 mH
Li = 0
Lo/Ro = 2.68 mH/Ω
• When used and installed in accordance with IEC/EN60079-25 and IEC/EN60079-14, Detective
NET is suitable for use in Zones 0, 1, 2 for Groups IIA, IIB or IIC and Temperature Classes T1 –
T4 provided any device(s) Detective NET is connected to also provides an appropriate Level of
Protection, Group Classification and Temperature Classification.
• The following conditions must also be met:
Other Device(s)
Other Device(s)
Ui> 3.7 V
Uo< 10 V
Ii > 14.3 mA
Io < 25 mA
Pi > 8.7 mW
Po < 62.5 mW
Ci + Ccable< 999 uF
Co > 240 nF
Li + Lcable< 173 mH
Lo >Lcable
• When Detective NET is connected to multiple other devices the system must be considered per
IEC/EN60079-25.
• Detective Net meets the dielectric strength requirement of clause 6.3.13 in IEC/EN60079-11.