Page of 15
8
INSTALLATION
1. POWER REQUIREMENT
AC single phase 230V (220-240V) 60HZ fused with a 50amp time delayed fuse or circuit breaker is
required. DO NOT OPERATE THIS UNIT if the ACTUAL power source voltage is less than 170 volts
AC or greater than 250 volts AC.
• High voltage danger from power source! Consult a qualified electrician for proper
installation of receptacle. This cutter must be grounded while in use to protect the operator
from electrical shock.
• Do not remove grounding prong or alter the plug in any way. Do not use any adapters
between the cutter’s power cord and the power source receptacle. Make sure the POWER
switch is OFF when connecting your cutter’s power cord to a properly grounded 230 VAC,
60Hz, 1 phase, 50 amp input power supply.
2. EXTENSION CORD - We do not recommend an extension cord because of the voltage drop they
produce. This drop in voltage can affect the performance of the welder. If you need to use an
extension cord, we recommend you check with a qualified electrician and your local electrical codes
for your specific area. Do not use an extension cord over 25 ft. in length.
3. INSTALLATION OF THE CUTTING TORCH
3.1 Your torch should be fully assembled and ready to install. The below figure shows the
components of the torch head and how those components are installed.
3.2 Connect the Pilot Arc cable (Red) on the plasma torch to the Arc Start Cable Connection.
3.3 Connect the Torch Control Cable (Black) 3 prong connector to the Arc Start Cable Connection.
3.4 Connect the Torch Weld Cable (Yellow Nut) to the Negative (-) output connection.
3.5 Connect the Grounding Cable to the Positive (+) output connection.
3.6 Connect the Ground Clamp to your workpiece.
3.7 Connect your compressed air source to the gas connection on this units back panel.
Содержание PC 375
Страница 15: ...Page of 15 13 Circuit Chart...