TABLE 1.2 Continued: 1586-0400431 Status Requests
TABLE 1.2 Continued: 1586-0400431 Status Requests
TABLE 1.2 Continued: 1586-0400431 Status Requests
Command
Syntax *
Description
Get Channel 3 Offset
{aaSc}
returns {aaScyy}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
c = command code (case sensitive, lower case c)
yy = Channel offset in dB.
The unit will reply with the '>' character if the command is sucessfully processed.
Get Channel 4 Gain
{aaSD}
returns {aaSDyyy.y}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
D = command code (case sensitive, capital D)
yyy.y = Channel gain in dB.
The unit will reply with the '>' character if the command is sucessfully processed.
Get Channel 4 Offset
{aaSd}
returns {aaSdyy}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
d = command code (case sensitive, lower case d)
yy = Channel offset in dB.
The unit will reply with the '>' character if the command is sucessfully processed.
Get Unit Alarm Status
{aaSL}
returns {aaSLx}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
L = command code
x = 0 for alarm off, 1 for alarm on.
The unit will append the '>' character if the command is sucessfully processed.
Get Product Info
{aaSV}
returns {aaSV1586-04-0431rev.5xx}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
V = command code
The unit will append the '>' character if the command is sucessfully processed.
returns {aaSixxx.xxx.xxx.xxx}
1586-04-0431 Manual
Page 9
4/12/21