48
3.4.5
Standby mode
This mode can only be activated by the Bluetooth application or the CAN-BUS.
Standby mode allows the charger to operate while the AC network is off. The aim is to monitor or configure the
charger without power supply from the input network. In this mode, the chargers are powered by the batteries
connected to the output. The default value is 600 seconds (10 minutes) used to safely change the energy unit setting.
The charger switches off if the output voltage drops below 9.9V (for 12V batteries).
If the charger is not used for more than 4 weeks in this standby mode, disconnect all the batteries connected to the
charger in order to avoid any discharge due to continuous consumption.
Comsumption in STANDBY mode :
3.4.6
Output current limitation
This mode can only be activated by the Bluetooth application or the CAN-Bus.
The
charger has an output current limitation, so the charger will be
able to deliver a percentage of the nominal current defined by the user.
3.4.7
Factory settings
The charger's factory settings are:
sealed lead, BOOST ON, REFRESH OFF, STANDBY OFF
This setting is a compromise for satisfactory recharging of different technologies of battery:
-
Classic sealed type
-
Sealed, Gel or AGM
-
Spiral sealed
-
Lithium iron phosphate (LiFePO4) with BMS
To define the charge in function of your battery, please refer to the chart, paragraph: 3.3.2.
For specific batteries, please call a professional installer, who will make the specific settings in accordance with battery
manufacturer's specifications and installation characteristics.
CRISTEC is not liable for any damage caused to the batteries or for inefficient recharging.
Nominal voltage
Without Bluetooth
With Bluetooth
12V
3.3mA
4.4mA