45
3.3.2
Programming Field 1: Select battery type
Configuration according to type of batteries 12V =
Setting
Description of the battery
type
FLOATING
voltage
12V
BOOST
voltage
12V
Maximum
duration of
BOOST at
+/- 5% T
BOOST
Maximum
duration of
ABSOPTION at
+/- 5% T
ABS
0
Opened type bat
free electrolyte (wet)
13.4V
14.1V
2H
4H
1
Classic sealed type bat
(Sealed Lead)
13.8V
14.4V
2H
4H
Factory setting
2
GEL type bat
13.8V
14.4V
2H
4H
3
AGM type bat**
13.6V
14.4V
2H
4H
4
Spiral type bat
13.6V
14.4V
2H
4H
5
Tin calcium lead bat
14.4V
15.1V
2H
4H
6
Wintering or standby sealed
bat
13.4V
13.4V
0H
0H
7
Stabilized DC power supply
12.0V
12.0V
0H
0H
8
SPE1 open type bat
13.2V
14.8V
2H
4H
9
Lithium iron phosphate
(LiFePO4) with BMS (***)
13.8V
14.4V
6H
1H
10
STORMLINE Bat
13.7V
14.5V
2H
6H
11
Specific
12.0V
12.0V
0H
0H
12
Specific
12.0V
12.0V
0H
0H
13
---
Customizable with Bluetooth
14
---
Customizable with CAN-Bus
15
---
Unused
Some specific settings are possible
–
please consult us.
(*)
Voltage on + BAT1, + BAT2, + BAT3 and + BATE, with 10% of the rated current and a tolerance of +/- 1%.
(
**
)
REFRESH is not advised for certain types of AGM batteries
(***) Battery Management System
3.3.3
Programming Field 2: Modify BOOST and REFRESH modes
Setting
REFRESH Mode
BOOST mode
0
OFF
OFF
1
OFF
ON
Factory setting
2
ON
OFF
3
ON
ON
-
The BOOST function allows a faster charging of the batteries. This function is time controlled (see section
BOOST mode to Float mode (see 3.5) for a battery current <20% of the nominal current of the charger (12% in
the case of the Lithium curve Iron Phosphate with BMS).