background image

 

Crestron

 TPS-ENET 

Ethernet Card for TPS/Tilt Panel 
Operations & Installation Guide 

 

 

Содержание TPS-ENET

Страница 1: ...Crestron TPS ENET Ethernet Card for TPS Tilt Panel Operations Installation Guide ...

Страница 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2002 Crestron Electronics Inc ...

Страница 3: ...ion and Hookup 5 Obtaining Communications 9 Ethernet Setup 13 Communicating with the Touchpanel via Ethernet 15 Programming 16 Programming with the Crestron AppBuilder 17 Programming with SIMPL Windows 18 Problem Solving 21 Troubleshooting 21 Further Inquiries 22 Firmware Upgrades 22 Future Updates 22 Return and Warranty Policies 23 Merchandise Returns Repair Service 23 CRESTRON Limited Warranty 2...

Страница 4: ......

Страница 5: ...ce connected to the Crestron remote control system herein referred to as the Cresnet system The TPS ENET also allows a TPS touchpanel to communicate through Ethernet with multiple control systems Refer to Ethernet Setup on pages 13 15 For additional information refer to the Ethernet Touchpanels and IP Table Setup sections of the latest revision of the Crestron e Control Reference Guide Doc 6052 Th...

Страница 6: ...r link status and YELLOW for Ethernet activity Dimensions Weight Height 0 64 in 1 61 cm Width 1 13 in 2 86 cm Depth 5 75 in 14 61 cm Weight 1 20 oz 0 03 kg 1 The latest versions can be obtained from the Downloads Software Updates section of the Crestron website www crestron com Refer to NOTE after last footnote 2 Crestron 2 Series control systems include the AV2 PAC2 PRO2 and RACK2 3 CNX update fi...

Страница 7: ...rcuit board PCB that is designed to be installed in a specific expansion slot on the touchpanel motherboard The card contains a 40 pin connector that attaches directly to the motherboard and the card is secured with two mounting screws supplied with TPS ENET An 8 position RJ45 port labeled LAN on the touchpanel is permanently attached to the motherboard and is accessible through the connector pane...

Страница 8: ...restron TPS ENET TPS ENET Physical Views TPS ENET Side View 0 631 in 1 603 cm Touchpanel connector TPS ENET Top View 5 750 in 14 605 cm 1 125 in 2 858 cm 4 Ethernet Card for TPS Tilt Panel TPS ENET Operations Installation Guide DOC 6016 ...

Страница 9: ...ns 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Setup Installation and Hookup The TPS ENET is designed to be installed in a specific expansion slot in the TPS 5000 and TPS 6000 touchpanels The tools required for installation are a grounding strap or grounded workstation and a 1 Phi...

Страница 10: ... optional external AC power pack is utilized disconnect the plug of the power pack from the touchpanel rear port labeled 24VDC 2A 2 To prevent errors when re connecting label and disconnect all cables attached to the touchpanel rear panel ports 3 If necessary use the touchpanel position lock buttons to adjust the touchscreen to the maximum most vertical upright angle 4 To prevent scratching of the...

Страница 11: ...uchpanel Base Cover 9 As shown on next page align the pins on the touchpanel interface connector of the TPS ENET with the touchpanel motherboard connector DO NOT force pins into connector Press TPS ENET until pins are fully seated Make sure that the screw holes of the card align with the mounting posts on the motherboard Operations Installation Guide DOC 6016 Ethernet Card for TPS Tilt Panel TPS E...

Страница 12: ...nstall the two card mounting screws supplied tighten to finger tight then using a 1 Philips screwdriver tighten an additional 1 8 turn Install TPS ENET Mounting Screws 11 Position the touchpanel base cover on the base 8 Ethernet Card for TPS Tilt Panel TPS ENET Operations Installation Guide DOC 6016 ...

Страница 13: ...nect all cables to the appropriate touchpanel rear panel ports 16 If the optional external AC power pack is utilized connect the plug of the power pack to the touchpanel rear port labeled 24VDC 2A Obtaining Communications To setup the touchpanel for Ethernet communication it is necessary to first obtain communication with the device Communication with the touchpanel can be established via the loca...

Страница 14: ...ning 2 Select Start Programs Crestron SIMPL Windows to start SIMPL Windows 3 SIMPL Windows responds with an opening splash screen and may display the What do you want to do window If so close the window 4 As shown below select Tools Viewport to open the Crestron Viewport window Accessing the Viewport 5 Refer to the graphic on next page While the Viewport is displayed select Setup Communications al...

Страница 15: ...32 Menu of the configured touchpanel If not the Viewport settings can be modified to match the touchpanel settings or the touchpanel settings can be modified to match the Viewport NOTE The Port Settings window refer to graphic on next page shows the default RS 232 settings Baud Rate 115200 Parity None Data Bits Eight and Stop Bits One for TPS panels when shipped from the factory Operations Install...

Страница 16: ...E To establish a remote console connection the control system must contain an appropriate update cuz file Refer to the Specifications on page 2 for the minimum version required for a remote console connection 1 If using the Stand alone Viewport open the Viewport and proceed to step 5 To access the Viewport via SIMPL Windows select Start Programs Crestron SIMPL Windows to start SIMPL Windows 2 SIMP...

Страница 17: ...net Setup Ethernet configuration is only performed via the touchpanel console and not available through Viewport setup screens This section contains the console commands required to setup the TPS touchpanel s for Ethernet operation To setup the touchpanel for Ethernet operation perform an appropriate section of Obtaining Communication on page 9 then enter the desired commands An example Ethernet s...

Страница 18: ...ebsite www crestron com NOTE For Ethernet communication IP tables must be set up in the control system and touchpanel Refer to the IP Table Setup section of the latest revision of the Crestron e Control Reference Guide Doc 6052 The latest version can be obtained from the Downloads Product Manuals section of Crestron s website www crestron com NOTE Some of the specific console commands are listed b...

Страница 19: ...MASK 255 255 255 0 Sets subnet mask for LAN to which the touchpanel is attached Communicating with the Touchpanel via Ethernet After Ethernet parameters have been configured on the touchpanel the Crestron Viewport may be used to communicate with the touchpanel To connect the Viewport to the touchpanel perform the following procedure NOTE Make sure the remote console is disconnected 1 In the Viewpo...

Страница 20: ...rd in the window 4 As shown below left enter the required password The correct password must be entered within three attempts or the password window shown below right displays a password invalid message Password Windows 5 Observe the Viewport connect to the touchpanel Programming You can create a program that allows you to control the TPS ENET equipped TPS touchpanel via Ethernet through a Crestro...

Страница 21: ...tion home theater video conferencing and lighting The interface of this tool guides you through a few basic steps for designating rooms and specifying the control system touchpanels devices and functionality The Crestron AppBuilder then programs the system including all touchpanel projects and control system logic The Crestron AppBuilder is fully integrated with Crestron s suite of software develo...

Страница 22: ... functionality in a familiar Windows environment This section explains how to create a SIMPL Windows program that includes a TPS ENET equipped touchpanel Configuration Manager is where programmers build a Crestron control system by selecting hardware from the Device Library In Configuration Manager drag the PRO2 from the Control Systems folder of the Device Library and drop it in the upper pane of...

Страница 23: ...Control Cards Cards 2 Series Z Bus folder of the Device Library and drop it on the PRO2 C2Z Card Slot in System Views The System Views upper pane displays the Ethernet Units icon below the PRO2 graphic The PRO2 system tree displays the C2ENET 2 in Slot 8 as shown below C2ENET 2 Device Slot 8 Drag the appropriate Ethernet TPS touchpanel for example the TPS 6000 w TPS ENET from the Touchpanels folde...

Страница 24: ...nel that contains the TPS ENETL refer to the IP Table Setup section of the latest revision of the Crestron e Control Reference Guide Doc 6052 The latest version can be obtained from the Downloads Product Manuals section of Crestron s website www crestron com Example Program An example program for the TPS touchpanel with TPS ENET is available from the Crestron FTP site ftp ftp crestron com Select t...

Страница 25: ...hpanel Wired select from Touchpanel Ethernet TPS ENET improperly installed Follow installation procedures in this guide Damaged connector pins Inspect connector pins If bent carefully re straighten If broken contact Crestron customer service Another device set to same IP address Obtain new touchpanel static IP address Possible bad port on hub Use crossover cable to connect directly to PC and ping ...

Страница 26: ...dates asp for the latest version of firmware Not every product has a firmware upgrade but as Crestron improves functions adds new features and extends the capabilities of its products firmware upgrades are posted If you have questions regarding upgrades procedures contact Crestron customer service Future Updates As Crestron improves functions adds new features and extends the capabilities of the T...

Страница 27: ...amps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been su...

Страница 28: ...Crestron Electronics Inc Operations Installation Guide DOC 6016 15 Volvo Drive Rockleigh NJ 07647 08 02 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...