![Crestron Sonnex SWAMP(I)-24X8 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/crestron/sonnex-swamp-i-24x8/sonnex-swamp-i-24x8_operation-manual_2684848024.webp)
Sonnex Multiroom Audio System
Crestron
SWAMP(I)-24X8
18
•
Sonnex Multiroom Audio System: SWAMP(I)-24X8
Operations Guide – DOC. 7049E
When setting the Net ID, consider the following:
•
The Net ID of each unit must match an ID code specified in the Crestron
Studio™ or SIMPL Windows program.
•
Each network device must have a unique Net ID.
IP ID
The IP ID is set from the SWAMP-24X8’s front panel or within the
SWAMP-24X8’s IP table using Crestron Toolbox. For more details, refer to “Set the
IP ID” which starts on page 39 or the Crestron Toolbox help file. The IP IDs of
multiple SWAMP-24X8 devices in the same system must be unique.
When setting the IP ID, consider the following:
•
The IP ID of each unit must match an IP ID specified in the Crestron Studio
or SIMPL Windows program.
•
Each device using IP to communicate with a control system must have a
unique IP ID.
Installation
Ventilation
The SWAMP-24X8 should be used in a well-ventilated area. The venting holes
should not be obstructed under any circumstances.
To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range listed in the table of specifications. Consider using
forced air ventilation or incrementing the spacing between units to reduce
overheating. Contact with thermal insulating materials should be avoided on all sides
of the unit.
Rack Mounting
The SWAMP-24X8 can be mounted in a rack or stacked with other equipment. Two
“ears” are provided with the SWAMP-24X8 so that the unit can be rack mounted.
These ears must be installed prior to mounting. Complete the following procedure to
attach the ears to the unit. The only tool required is a #1 or #2 Phillips screwdriver.
WARNING:
To prevent bodily injury when mounting or servicing this unit in a
rack, observe the following guidelines:
•
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
•
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
NOTE:
Observe the following guidelines when installing equipment in a rack:
•
Elevated Operating Ambient Temperature - If installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient temperature. Therefore,
consideration should be given to installing the equipment in an environment
compatible with the maximum ambient temperature (Tma) specified by the
manufacturer.
•
Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of airflow required for safe operation of the equipment is
not compromised.
•
Mechanical Loading - Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven mechanical
loading.
Содержание Sonnex SWAMP(I)-24X8
Страница 1: ...Crestron SWAMP I 24X8 Sonnex MultiroomAudioSystem Operations Guide ...
Страница 4: ......
Страница 6: ......