  85 

RC5 Codes Function Table (Continued) 

CODE 

FUNCTION 

Key 33 

N/A 

Key 34 

Last active scene up 

Key 35 

Last active scene down 

Key 36 

All lights up 

Key 37 

All lights down 

Key 38 

N/A 

Key 39 

N/A 

Key 40 

N/A 

Key 41 

Slave 1 Light Zone 1 Up 

Key 42 

Slave 1 Light Zone 1 Down 

Key 43 

Slave 1 Light Zone 2 Up 

Key 44 

Slave 1 Light Zone 2 Down 

Key 45 

Slave 1 Light Zone 3 Up 

Key 46 

Slave 1 Light Zone 3 Down 

Key 47 

Slave 1 Light Zone 4 Up 

Key 48 

Slave 1 Light Zone 4 Down 

Key 49 

Slave 1 Light Zone 5 Up 

Key 50 

Slave 1 Light Zone 5 Down 

Key 51 

Slave 1 Light Zone 6 Up 

Key 52 

Slave 1 Light Zone 6 Down 

Key 53 

Slave 2 Light Zone 1 Up 

Key 54 

Slave 2 Light Zone 1 Down 

Key 55 

Slave 2 Light Zone 2 Up 

Key 56 

Slave 2 Light Zone 2 Down 

Key 57 

Slave 2 Light Zone 3 Up 

Key 58 

Slave 2 Light Zone 3 Down 

Key 59 

Slave 2 Light Zone 4 Up 

Key 60 

Slave 2 Light Zone 4 Down 

Key 61 

Slave 2 Light Zone 5 Up 

Key 62 

Slave 2 Light Zone 5 Down 

Key 63 

Slave 2 Light Zone 6 Up 

Key 64 

Slave 2 Light Zone 6 Down 

 

Содержание iLux CLS-C6

Страница 1: ...Crestron CLS CLSI C6 CLS CLSI C6M iLux IntegratedLightingSystem Operations Guide ...

Страница 2: ...en tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling Federal Communications Commission FCC Compliance Statement CAUTION Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to ...

Страница 3: ...s for the PC 28 Programming with SystemBuilder 28 Programming with D3 Pro 28 Programming with SIMPL Windows 29 Uploading and Upgrading 31 Establishing Communication 31 Programs and Firmware 32 Operation 33 Button Types 33 IR Receiver 36 Occupancy Sensing 36 Override Mode 36 Load Shedding Demand Response 37 Building Management System BMS Interface 37 Problem Solving 41 Troubleshooting 41 Check Netw...

Страница 4: ...ands 69 Override Commands 69 Load Shed Commands 70 Occupancy Commands 70 Photocell Commands 70 Version command 71 Appendix D Factory Default Values 72 Appendix E Button Functions 74 Appendix F Room Combining 81 Appendix G RC5 Code Expansion 84 Return and Warranty Policies 86 Merchandise Returns Repair Service 86 Crestron Limited Warranty 86 ...

Страница 5: ...is guide the term CLS C6 is used except where noted Features and Functions Continued on following page Wall mounted integrated lighting and shade control Six channels of dimming or switching Six groups of shade or drapery control Linkable for up to 54 lighting channels and 54 shade groups Up to 16 user settable scenes Seven configurable rocker buttons with customizable label strip Large ON and OFF...

Страница 6: ...e instant access to the On and All Off scenes while the six main buttons can be set up to recall additional scene presets adjust shades or perform a host of other functions The buttons rocker action enables intuitive tactile control for adjusting lighting levels and shade positions An additional Up Down button is configurable for a variety of functions including use as a master lighting or shade c...

Страница 7: ...te control sold separately Multipoint Keypad Control Up to 16 Crestron keypads may be connected to a single CLS C6 providing versatile multipoint control for rooms with multiple entrances or work areas Individual keypad buttons can be programmed to work through the master unit or can target specific slave units for maximum control and room management Touch Screen Support The CLS C6 can support up ...

Страница 8: ...oftware as well as third party SNMP software RS 232 Interface via C2N IO The CLS C6 can be controlled from a third party controller or a PC program via the ASCII command set The Crestron serial convertor module C2N IO sold separately is used to route packets between the CLS C6 and the third party controller The serial converter module translates ASCII strings to Cresnet serial packets and Cresnet ...

Страница 9: ...m Almond CLS CLSI C6B iLux Integrated Lighting System Black CLS CLSI C6W iLux Integrated Lighting System White CLS CLSI C6MA iLux Integrated Lighting System with Motion Detector Almond CLS CLSI C6MB iLux Integrated Lighting System with Motion Detector Black CLS CLSI C6MW iLux Integrated Lighting System with Motion Detector White Available Accessories C2N CBD P CBF P CBD E Cameo Keypad Standard Mou...

Страница 10: ...ypes can also be supported using Crestron CLS EXP Series expansion modules sold separately 3 The latest versions can be obtained from the Crestron Web site Refer to NOTE after last footnote 4 Crestron 2 Series control systems include the AV2 and PRO2 Consult the latest Crestron Product Catalog for a complete list of 2 Series control systems NOTE Crestron software and any files on the Web site are ...

Страница 11: ...6 C6M 7 CLS C6M Overall Dimensions 8 89 in 226 mm 4 48 in 114 mm 1 88 in 48 mm 2 38 in 60 mm 0 59 in 15 mm CLS C6 CLSI C6 0 72 in 18 mm CLS C6M CLSI C6M CLS C6M Front Panel Scene 1 Scene 2 Scene 3 Scene 4 Scene 5 Scene 6 Min Sec Lights Shades Save Cancel 1 2 3 4 5 6 ON OFF 1 2 3 4 6 8 5 9 10 11 13 14 15 7 12 CLS C6 Rear Panel 16 17 18 19 16 ...

Страница 12: ...onal Crestron remote control The remote control can be used to recall Scenes 1 4 the On and Off scenes and perform master raise and lower of the lighting loads 5 Motion Detector CLS CLSI C6M only The built in motion detector can be used to activate a particular scene when there is activity in the room and or to activate a particular scene typically Off when there is no activity for a specified per...

Страница 13: ...ix function buttons The unit must always be in upper or lower Shift mode as indicated by the state of the LEDs 13 Up Down Push button This three position rocker switch is programmable for master lights control all lights or last scene master shade control or as a shift button to allow a second set of functions for the six function buttons 14 ON Button The ON button always acts as a recall scene bu...

Страница 14: ...de The MNET ID of the SortName has been factory set to 1F After an infiNET device is added to an infiNET network its MNET ID must be changed to a value that can be addressed by the control system program 03 to 20 The MNET IDs of multiple SortName devices on the same gateway must be unique MNET IDs are changed from a personal computer PC via Crestron Toolbox refer to Establishing Communication on p...

Страница 15: ...controls without having to use a PC Changes to the lighting load levels and shade presets for one or more scenes can be accomplished as follows NOTE The iLux Designer or SIMPL Windows programs can lock a scene to prevent it from being changed using the front panel controls If an adjustment is made to a scene that is Er is displayed for 3 seconds The scene remains in its existing state 1 In Standar...

Страница 16: ...he Min and Sec LEDs light as appropriate Adjustment to fade time can be made when either Lights mode or Shades mode is active 9 When all the lighting loads are at the desired level and shades are at the desired position press Save to save these settings as the new preset for that scene If a mistake is made while changing a setting press Cancel to discard changes and return to Standard mode before ...

Страница 17: ...to accomplish scene changes as discussed in Changing Scene Presets on page 11 This method also allows settings to be changed for scenes greater than scene 6 Note that scenes can be turned off in addition to being recalled When a scene is turned off only the lighting loads are turned off If the scene contains any shades they are not affected The fade time for turning the scene lights off is the sam...

Страница 18: ...full close position The iLux Designer or SIMPL programs can lock a scene to prevent it from being changed using the front panel controls If the selected scene is locked in the configuration when an adjustment is made Er is displayed for 3 seconds and the scene remains in its existing state To adjust the fade time while Sc is displayed press the and v buttons to adjust the time The first time a but...

Страница 19: ...new load type listed in the above table Setup Low End Levels LE Some lights can flicker at very low levels To avoid this specify the low end limit accordingly When adjusting lights to a level below this value they stay at the low end limit until they are turned off To set the low end levels for the six lighting loads First enter Setup mode and scroll to the LE option using the and v buttons At thi...

Страница 20: ...has been made lights jump to the original high end level Light levels are not change on lighting loads where no adjustment was made When the Save button is pressed Setup mode is exited the new values are saved and the lights do not change Setup Button Functions bF This Setup mode is used to define the behavior of the buttons on the CLS C6 unit itself and on remote keypads if operation is desired o...

Страница 21: ... including shifted functions can be defined using the iLux Designer configuration program Setup Up Down Button Function ud To define operation of the up down button enter Setup mode and scroll to the ud option using the and v buttons Use the up down button to select the desired mode The display flips between ud and where is the mode as defined in the following table FUNCTION MODE Lights Last Scene...

Страница 22: ... and devices To enter this mode first enter Setup mode and scroll to the Ad option using the and v buttons Then press the up down button either top bottom or both and hold for 5 seconds The auto discovery process then starts If the button is released before 5 seconds are up nothing happens but Ad mode is locked in Once Ad mode is locked in the Cancel button flashes During Auto discovery the Ad dis...

Страница 23: ...any of these errors occur when the discovery process is done the two digit display flashes between Ad and E where is the total number of devices discovered on the network including invalid devices and E is E1 through E7 per the seven error types listed above If more than one error is present all error codes are displayed in sequence In such case the Save LED does not light the Cancel LED remains f...

Страница 24: ... is assigned to a new group it is removed from the first group Therefore if a shade controller is accidentally configured to the wrong group go to the correct group and reassign it Once all shade controllers are assigned press Save to save the assignments and return to Standard mode or press Cancel to discard the assignments Display Set MNET ID Of This Unit id If this unit is to be connected to a ...

Страница 25: ...ll NOTE Photocell calibration is best performed on a sunny day when all loads are above their minimum dim level but below 80 Performing photocell calibration when there is insufficient daylight may cause undesired operation on a bright day Conversely performing photocell calibration when there is excessive daylight may prematurely trigger loads to reach their minimum dim level refer to Photocell L...

Страница 26: ...ed by the current photocell level sensitivity and minimum dim level NOTE Attempting to adjust the sensitivity for loads not controlled by a photocell causes the 2 digit display to flash Er Press Save to save the new settings or Cancel to retain the original setting Photocell Lower Limit PL This Setup mode is used to adjust the lower limit for the photocell when Daylight Harvesting is enabled This ...

Страница 27: ...settings to their factory defaults 1 First enter Setup mode and then scroll to the Fd option using the and v buttons Then press the up down button either top bottom or both and hold for 5 seconds 2 This procedure is locked in and the Save LED flashes If the button is released before 5 seconds are up nothing happens Press Save all configuration items are set to their factory default values Press Ca...

Страница 28: ...ds specified limits 800 watts per load 1920 watts system maximum with a 20A breaker 1440 watts maximum with a 15A breaker and 1000 watts maximum with an Arc Fault breaker for a 120 VAC installation and 800 watts per load 2200 watts system maximum for a 220 VAC installation 2300 watts system maximum for a 230 VAC installation and 2400 watts system maximum for a 240 VAC installation Shades The Shade...

Страница 29: ...he Touchpanel screen allows up to two touch screens to be added enter unique names for the touch screen and buttons and define the action type action and target of each button on that touch screen NOTE All touch screen defined in the project must be installed and present on the CLS C6 network before sending Touch screen projects or setting Network IDs via the Finish screen Finish The Finish screen...

Страница 30: ...lighting loads are turned off In Glow mode all the white LEDs turn on at a very low level to make it possible to find the unit in a darkened room 1 Press the OFF button to select the Off scene all lights off 2 At the prompt type WHITELEDGLOWLEVEL and press Return The system displays White led glow level 7 iLux 3 To change the brightness type WHITELEDGLOWLEVEL where is any number from 1 to 100 The ...

Страница 31: ...e bottom edge 2 Carefully pull the label cover from the top edge at each side of the unit Refer to the following illustration 3 Remove the original label and replace it with the new label 4 Replace the label cover make sure the small tabs on the bottom edge are inserted in the slots on the unit cover and snap into position 5 Install the front cover assembly on the unit by lining it up at the top a...

Страница 32: ...LS C6 Customers whose focus is on lighting systems may prefer to use the D3 Pro software since it is designed especially for creating lighting and environmental system control applications Customers already familiar with SIMPL Windows who are including a lighting system as part of an overall control system project may prefer to continue using SIMPL Windows Programming with SystemBuilder SystemBuil...

Страница 33: ...nd Program Configuration Manager Configuration Manager is the view where programmers build a Crestron control system by selecting hardware from the Device Library 1 To incorporate the CLS C6 into the system drag the CLS C6 from the Lighting folder of the Device Library and drop it in the System Views Locating the CLS C6 in the Device Library The system tree of the control system displays the devic...

Страница 34: ...code specified in the SIMPL Windows program must match the Net ID of each unit Refer to Identity Code on page 10 Program Manager Program Manager is the view where programmers program a Crestron control system by assigning signals to symbols The symbol can be viewed by double clicking on the icon or dragging it into Detail View Each signal in the symbol is described in the SIMPL Windows help file F...

Страница 35: ...he CLS C6 connects to the serial port on the PC via a serial cable Crestron STCP 502 or equivalent 1 Use the Address Book in Crestron Toolbox to create an entry using the expected serial communication protocol RS 232 auto detect baud rate no parity 8 data bits 1 stop bit XON XOFF disabled RTS CTS disabled 2 Display the CLS C6 s System Info window click the icon communications are confirmed when th...

Страница 36: ...ware or to upload and upgrade via the Crestron Toolbox For details on uploading and upgrading refer to the SIMPL Windows help file or the Crestron Toolbox help file SIMPL Windows If a SIMPL Windows program is provided it can be uploaded to the control system using SIMPL Windows or Crestron Toolbox Firmware Check the Crestron Web site to find the latest firmware New users may be required to registe...

Страница 37: ...he up down push button can be defined to be either lights master or shades master If defined to be lights master it ramps the lighting loads included in the most recently recalled scene up and down Non dim loads are not affected If defined to be shades master all shade groups are affected Refer to Shades mode on page 39 for operating details Using the iLux Designer program this button may be assig...

Страница 38: ...abled on Recall scene buttons via the iLux Designer software and a scene is selected LED on steady the right and left sides of the function button can be used to raise and lower all dimmable lighting loads contained in that scene The ON button always acts as a recall scene button for the ON scene operating identically to other scene recall buttons except that items specific to dual buttons do not ...

Страница 39: ...n off the LED flashes until all affected lighting loads reach 0 After this the LED is off until any affected light turns on Pressing a scene button while its LED is flashing performs a scene cut during either recall or turn off Behavior of the two digit display is the same as for scene recall Master Last Scene Raise Lower Buttons Press the right side to raise lights the left side to lower release ...

Страница 40: ...e motion sensor timeout of each unit to the same value Otherwise operation may not be as expected External partition sensors provided by others connected via the GLS SIM product enable additional actions such as room combining Refer to Appendix F Room Combining on page 81 for additional details Setting a GLS SIM to the designated Cresnet ID 0xC0 or 0xC1 causes this GLS SIM to behave like an extern...

Страница 41: ...ode the 7 segment display shall flash LS at a rate of 1 second on 1 second off unless the display is actively showing something else Using iLux Designer any value can be entered into the Load Shed Max field 0 100 The default Load Shed Max value in iLux Designer is 80 for all loads Building Management System BMS Interface A DIN IO8 unit is supported for the purpose of providing a contact closure in...

Страница 42: ...s for going from full off to full on This can be adjusted using the iLux Designer software Non dim lighting loads go immediately to full on or full off The bar graphs indicate current light level The two digit display indicates the current percentage level of the lighting load being adjusted oF 01 to 99 on This display goes blank 3 seconds after the last adjustment While the front panel button is ...

Страница 43: ...e shade group being adjusted CL 01 to 99 OP The two digit display disappears goes blank 3 seconds after the shade stops moving due to either a stop command or reaching a limit of travel NOTE The two digit display only shows the shade level when being adjusted from front panel buttons in Shades mode or scene programming It does not display when adjusting levels from a remote panel or Cresnet For sh...

Страница 44: ... To manually adjust this channel after that release and re press the button The unit remains in Shades mode To exit Shades mode press the Shades button again or press the Cancel button the LED extinguishes and the unit returns to Standard mode Also pressing the Lights button automatically exits Shades mode and enters Lights mode If no adjustments are made for 1 minute the unit automatically revert...

Страница 45: ...than fade More than one iLux unit picking up IR command Disable IR function on all but one unit Motion detector does not function Occupancy sensor function is not enabled Use iLux Designer or front panel setup function to enable occupancy sensor Check Network Wiring Use the Right Wire To ensure optimum performance over the full range of the installation topology use Crestron Certified Wire only Fa...

Страница 46: ...sted pair is the 24V conductor and the GND conductor and the other twisted pair is the Y conductor and the Z conductor Strip and Tin Wire When daisy chaining Cresnet units strip the ends of the wires carefully to avoid nicking the conductors Twist together the ends of the wires that share a pin on the network connector and tin the twisted connection Apply solder only to the ends of the twisted wir...

Страница 47: ...lly benefit from all available features Future Updates As Crestron improves functions adds new features and extends the capabilities of the CLS C6 CLS C6M CLSI C6 and CLSI C6M additional information may be made available as manual updates These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision Check the Crestron ...

Страница 48: ...pad types currently supported These settings can be changed using the front panel Setup mode or via iLux Designer Supported Keypads KEYPAD TYPE BUTTON LAYOUT BUTTON NUMBER DEFAULT FUNCTION CNX B2 1 2 1 Recall ON Scene 2 Recall OFF Scene CNX B4 1 2 1 2 3 4 1 Recall ON Scene 2 Recall OFF Scene 3 Last Scene Up 4 Last Scene Down CNX B6 C2N DB6 1 3 5 2 4 6 1 Recall Scene 1 2 Recall Scene 2 3 Recall Sce...

Страница 49: ...ene Down 10 Last Scene Up 11 Recall OFF Scene 12 Recall ON Scene C2N CBD C2N CBF 1 2 3 4 5 6 1 Recall On Scene 2 Recall Scene 1 3 Recall Scene 2 4 Recall Off Scene 5 Master Raise last scene 6 Master Lower last scene C2N CBD P C2N CBD E C2N CBF P On Scene 1 Scene 2 Scene 3 Off 1 On 2 Scene 1 3 Scene 2 4 Scene 3 5L Last Scene Down 5R Last Scene Up 6 Off C2NI CB INETI CB 1L 3L 5L 2L 4L 6L 1R 3R 5R 2R...

Страница 50: ...tively Touch screen display lists can be transferred to the touch screen via the programming jack on the iLux Through the use of the join map shown in the tables on the following page in conjunction with D Nav on the touch screen itself a touch screen connected directly to an iLux provides the following functionality Showing bar graphs indicating the current state of all loads on the master iLux A...

Страница 51: ... 1 full stop 247 Shade group 1 open momentary 248 Shade group 1 close momentary 249 Shade group 1 open jog 250 Shade group 1 close jog 251 Shade group 1 full open momentary open 252 Shade group 1 full close momentary close 253 Shade group 1 full open stop close stop 254 263 Shade group 2 control 264 273 Shade group 3 control 274 283 Shade group 4 control 284 293 Shade group 5 control 294 303 Shade...

Страница 52: ...l enable light zone 4 510 Photocell enable light zone 5 511 Photocell enable light zone 6 512 Photocell disable light zone 1 513 Photocell disable light zone 2 514 Photocell disable light zone 3 515 Photocell disable light zone 4 516 Photocell disable light zone 5 517 Photocell disable light zone 6 518 Photocell sensitivity level up light zone 1 519 Photocell sensitivity level up light zone 2 520 ...

Страница 53: ...1649 Same as joins 100 499 and 506 541 but for CLS C6 Slave 2 1650 2199 Same as joins 100 499 and 506 541 but for CLS C6 Slave 3 2200 2749 Same as joins 100 499 and 506 541 but for CLS C6 Slave 4 2750 3299 Same as joins 100 499 and 506 541 but for CLS C6 Slave 5 3300 3840 Same as joins 100 499 and 506 541 but for CLS C6 Slave 6 3850 4391 Same as joins 100 499 and 506 541 but for CLS C6 Slave 7 440...

Страница 54: ...ene is locked 6269 Fade time shown is in minutes 6270 Motion activity 6271 Function activity 6272 Current occupancy state 6274 Entry scene enabled 6278 Exit scene enabled 6280 6311 Not supported note external button fb is sent at same join number 6312 In Override mode 6313 In Load shed mode 6320 6355 Partition 1 36 is open rooms are combined 6358 Photocell enable feedback light zone 1 6359 Photoce...

Страница 55: ...9 same as joins 20 39 for slave 3 100 119 same as joins 20 39 for slave 4 120 139 same as joins 20 39 for slave 5 140 159 same as joins 20 39 for slave 6 160 179 same as joins 20 39 for slave 7 180 199 same as joins 20 39 for slave 8 Analog Feedback Joins Analog Feedback Joins from CLS C6 to Touch Screen JOIN DESCRIPTION 20 25 current light levels for loads 1 6 26 31 current position for shade gro...

Страница 56: ...t zone 6 506 Photocell level feedback 507 Photocell Dim min level feedback light zone 1 508 Photocell Dim min level feedback light zone 2 509 Photocell Dim min level feedback light zone 3 510 Photocell Dim min level feedback light zone 4 511 Photocell Dim min level feedback light zone 5 512 Photocell Dim min level feedback light zone 6 513 Photocell response time feedback 520 539 Same as joins 500...

Страница 57: ... response time feedback string for slave 1 531 Photocell response time feedback string for slave 2 731 Photocell response time feedback string for slave 3 931 Photocell response time feedback string for slave 4 1131 Photocell response time feedback string for slave 5 1331 Photocell response time feedback string for slave 6 1531 Photocell response time feedback string for slave 7 1731 Photocell res...

Страница 58: ...s to factory default SYSTEM load firmware to iLux UPLOAD load firmware to cresnet device on the local network VERSION display firmware version number WHITELEDLEVEL display or set white leds brightness level WHITELEDGLOWLEVEL display or set white leds glow brightness level iLux The commands are presented alphabetically in the following listing Details about each command include a description of the...

Страница 59: ... of all commands CATEGORY to show a list of commands in that category None to display a list of all categories INFO Description Use this command to display additional device information For example this command would produce information similar to the following Application version 1 01 02 Loader version 1 16 00 Config data version 1 1 User data version 1 0 Help Menu s Common System Syntax INFO Par...

Страница 60: ... only valid parameter value REBOOT Description Use this command to reboot the CLS C6 Help Menu s Common Syntax REBOOT Parameters None REPORTCRESNET Description Use this command to report devices on the local network Help Menu s Common Syntax REPORTCRESNET ID REPORTCRESNET ALL Parameters 03 FE to identify a specific device ALL To show all devices on the network RESTORE Description Use this command ...

Страница 61: ...iption Use this command to display or set white LEDs brightness level Refer to LED Brightness on page 26 for details Help Menu s Device Syntax WHITELEDLEVEL nnn WHITELEDLEVEL Parameters 0 100 to set brightness level none to display current brightness level WHITELEDGLOWLEVEL Description Use this command to display or set white LEDs glow brightness level Refer to Glow Mode Brightness on page 26 for ...

Страница 62: ... If the PC is connected to the CLS C6 and the C2N IO serially at the same time then choose a different port for the C2N IO since the serial connection is not shared COM1 COM2 COM6 This can be performed in the Crestron Toolbox Address Book when selecting the communications settings for the C2N IO Command Format All packets from the third party equipment shall be in ASCII character set range 0 to 12...

Страница 63: ...e 2 This response packet is returned if command requires status or reply packet from the controller Response Par1 Parx 0Dh 0Ah Response Packet Type 3 This response packet is returned if there was no packet error and a status or reply packet response is not required OK 0Dh 0Ah iLux Controller Code Table CONTROLLER CODES DESCRIPTION M Commands the iLux Master Controller S1 S8 Commands the iLux Slave...

Страница 64: ...MIT1 LIMIT6 Light zone programming Read Light zone max level ILUX LZ X ALL MAX ILUX LZ X ALL MAX LIMIT1 LIMIT6 Light zone programming Read Light zone names ILUX LZ X NAME ILUX LZ X NAME LABEL Shade group Control Set Shade group position ILUX SZ X ALL POS LEVEL Shade group Control Get Shade group position ILUX SZ X ALL POS ILUX SZ X ALL POS LEVEL1 LEVEL6 Shade group Control Shade group Open ILUX SZ...

Страница 65: ...ILUX SC XX LZMSK VALUE Scene programming Read scene light mask ILUX SC XX LZMSK ILUX SC XX LZMSK VALUE Scene programming Set scene shade mask ILUX SC XX SZMSK VALUE Scene programming Read scene shade mask ILUX SC XX SZMSK ILUX SC XX SZMSK VALUE Scene programming Read scene name ILUX SC XX NAME ILUX SC XX NAME LABEL Combine Uncombined Combine rooms ILUX COM ILUX1 ILUX2 Combine Uncombined Uncombined...

Страница 66: ... and run the auto discover from CLS C6 front panel CLS C6 adds the device to its network list The CLS C6 then polls and configures the C2N IO serial port The C2N IO serial port baud rate settings are 9600 8 data bits 1 stop bit XON XOFF disabled RTS CTS disabled Echo Control Command This command is used to enable disable character echo Syntax ILUX Echo ON OFF Light Zone Commands Light Zone Operati...

Страница 67: ... second steps e g 100 1 seconds Light Zone Stop Command The following command is used to stop the light zone control Syntax ILUX LZ X ALL STOP X 1 6 light zone ALL All Light zones STOP Stop light level Light Zone Toggle Command The following command is used to toggle the light zone Internal fade time is used if fade time is not entered Syntax ILUX LZ X ALL TOG FADETIME X 1 6 light zone ALL All lig...

Страница 68: ...load types This command is not supported for slave CLS C6 controllers Syntax M LZ X ALL TYPE X 1 6 light zone Reply packet M LZ X ALL TYPE CODE1 CODE6 CODEx refer to table below type code for light zone through 6 Light Zone Load Type Codes SUPPORTED TYPES CODE DESCRIPTION 0 Unused 1 Non dimmer 2 Incandescent 3 Magnetic low voltage 4 Cold Cathode 5 Fluorescent 2 wire 6 Fluorescent 3 wire 7 Fluoresc...

Страница 69: ...1 LEVEL6 LEVELx 0 100 for shade group 1 6 Shade Group Open Close and Stop Command The following command is used to open close or stop shade group s Syntax ILUX SZ X ALL OPEN CLOSE STOP X 1 6 Shade group ALL All shade groups Shade Group Jog Open and Close Command The following command is used to jog open or jog close the shade group s Syntax ILUX SZ X ALL JOPEN JCLOSE X 1 6 Shade group ALL All shad...

Страница 70: ...e group 1 6 Shade Type Codes CODE SHADE TYPES 20 Somfy shade controller 21 SDC 4 relay shade controller 22 SDC DC shade controller Scene Commands Scene Operating Commands Scene Recall The following command is used to recall scene Syntax ILUX SC XX RECALL Recall Scene Commands SCENE NUMBER XX DESCRIPTION ON On Scene OFF Off Scene 1 15 Scene 1 15 Scene Raise Lower and Stop Command The following comm...

Страница 71: ... mask Bit0 Bit16 Bit0 off scene state Bit1 On scene state Bit2 Bit16 Scene1 Scene15 Scene Programming Commands Scene Quick Save Command This command is used to save current light levels for selected scene Syntax ILUX SC XX SAVE XX ON 1 15 Scenes Scene Query Light Zone Level Command This command is used to read light level in scenes This command is not supported for slave CLS C6 devices Syntax M SC...

Страница 72: ...for slave CLS C6 devices Syntax M SC XX LZMSK XX OFF ON 1 15 Scenes Reply packet M SC XX LZMSK VALUE Scene Shade Mask Command This command is used to remove or add shade group to scenes This command is not supported for slave CLS C6 devices Syntax M SC XX SZMSK VALUE XX OFF ON 1 15 scene VALUE 0 63 1 Add 0 Remove bit0 bit5 Shade group 1 Shade group6 Scene Shade Status Command This command is used ...

Страница 73: ...d for slave CLS C6 devices Syntax M UNCOMBINE ILUX1 ILUX2 ILUXx M for master S1 S8 for slaves Query Combine Status This command is used to query room combine status This command is not supported for slave CLS C6 devices Syntax M COMBINE ILUX1 ILUX2 Reply packet M COMBINE STATUS STATUS YES NO Override Commands Override Mode Override On Command The following command is used to turn on override Synta...

Страница 74: ...Commands Occupancy Operation Commands Occupancy State Set Clear Command The following command is used to set or clear occupancy state All occupancy sources are ORED together Command not supported for slave ilux If master and slave s iluxes are linked the occupancy state is forwarded to all iluxes Syntax M OC SET CLEAR Occupancy State Query Command The following command is used to query occupancy s...

Страница 75: ...tions Guide DOC 6347E iLux Integrated Lighting System CLS C6 C6M CLSI C6 C6M 71 Version command The following command is used to query version string This command is not supported for slave CLS C6 devices Syntax M VER Reply packet M VER CLS C6M TEST VER v2 01 02 12345678 ...

Страница 76: ...to 45 no shades Scene 4 2 seconds fade all 6 lighting loads to 60 no shades Scene 5 2 seconds fade all 6 lighting loads to 75 no shades Scene 6 2 seconds fade all 6 lighting loads to 90 no shades Scene 7 2 seconds fade all 6 lighting loads to 15 no shades Scene 8 2 seconds fade all 6 lighting loads to 30 no shades Scene 9 2 seconds fade all 6 lighting loads to 45 no shades Scene 10 2 seconds fade ...

Страница 77: ...d Lighting System CLS C6 C6M CLSI C6 C6M 73 Factory Default Values Continued ITEM DEFAULT VALUE Green LED brightness level 63 White LED brightness level 70 White LED glow level 7 The Cresnet ID default 1F in the configuration memory is not be affected by the Fd function unless configuration data is corrupt ...

Страница 78: ...what their target levels should be all lighting loads go to full off definitely causing air gap relay to open Fade time and shade behavior can still be specified LED action Flash while lights are actively fading Scene interlocked afterwards Note that for Recall Off Scene LED is on when all lights are off LED goes on when scene is recalled LED remains on until another scene is recalled or Lights_in...

Страница 79: ...avior The specified lighting load raises as long as the button is held it stops when button released Rate is the global ramp rate If they hit the High End limit the lights stop at that point but the bar graph display continues to rise If going up from OFF lights immediately go to the Low End limit and the bar graph display starts rising from 0 When the display i e the internal ramp value reaches t...

Страница 80: ...emote Button Rocker Behavior Left right and center all do the same thing Notes N A Function name Master Lower Lighting Loads Last Scene All Lights On scene Scenes 1 15 Behavior Same as Lower Lighting Load except acts on all dimmable Lighting Loads affected by the specified scene All lights ramp at the same rate Non dim loads are not affected Shades are not affected LED On while button is pressed A...

Страница 81: ...ffect all the shade groups connected to the given CLS C6 module They do not pass from one CLS C6 module to another either when directly connected or when linked through a Cresnet system If all shades are to open in a multi unit system define a scene to do that Function name Close Shades Full All Group 1 6 Behavior Sends the specified shades to Full Closed position LED On while button is pressed Ap...

Страница 82: ...irectly connected or when linked through Cresnet system To accomplish this function for all shades in a multi unit system use SIMPL programming Function name Jog Shades Open All Group 1 6 Behavior Specified shades move toward the Open position for the specified jog time and then stop LED On while button is pressed Applies To Remote Button Rocker Behavior N A Notes Jog time defaults to 0 05 sec Oth...

Страница 83: ...onnected or when linked through Cresnet system To accomplish this function for all shades in a multi unit system use SIMPL programming Function name Close Momentary Close Full All Group 1 6 Behavior Same as Open Momentary Open Full Shade Group 1 6 except Close LED On while button is pressed Applies To Remote Button Rocker Behavior N A Notes Same as Open Momentary Open Full Shade Group 1 6 Function...

Страница 84: ...xternal Function 1 2 31 32 Behavior Activates the corresponding press digital signal press1 press32 on the External Functions slot on the Cresnet system connected to the CONTROL SYSTEM port Signal remains high for as long as the button is pressed The left button corresponds to the lower number The right button corresponds to the higher number LED On if feedback for either join number is high off i...

Страница 85: ...partition sensors Refer to the latest version of the GLS SIM Installation and Operations guide Doc 6768 for details on how to set the DIP switches appropriately Keep the following in mind Use only input channel 1 on the GLS SIM when used for partition sensing When using normal polarity the presence of a contact closure or voltage below threshold indicates that a partition is CLOSED rooms are separ...

Страница 86: ...sor Example 3 One Small and one Large Room MASTER SLAVE 1 ID 90 SLAVE 2 M S1 GLS SIM Partition Master Slave 1 Partition Sensor In example 3 above since there are no partitions separating Slave 1 and Slave 2 or Master and Slave 2 iLux Designer software must be used to indicate the default status of these missing partitions In this case the following defaults should be set Master Slave 1 default can...

Страница 87: ...x97 Slave 1 Slave 2 0x98 Slave 1 Slave 3 0x99 Slave 1 Slave 4 0x9A Slave 1 Slave 5 0x9B Slave 1 Slave 6 0x9C Slave 1 Slave 7 0x9D Slave 1 Slave 8 0x9E Slave 2 Slave 3 0x9F Slave 2 Slave 4 0xA0 Slave 2 Slave 5 0xA1 Slave 2 Slave 6 0xA2 Slave 2 Slave 7 0xA3 Slave 2 Slave 8 0xA4 Slave 3 Slave 4 0xA5 Slave 3 Slave 5 0xA6 Slave 3 Slave 6 0xA7 Slave 3 Slave 7 0xA8 Slave 3 Slave 8 0xA9 Slave 4 Slave 5 0x...

Страница 88: ...ey 3 Scene 1 Key 4 Scene 2 Key 5 Scene 3 Key 6 Scene 4 Key 7 Scene 5 Key 8 Scene 6 Key 9 Scene 7 Key 10 Scene 8 Key 11 Scene 9 Key 12 Scene 10 Key 13 Scene 11 Key 14 Scene 12 Key 15 Scene 13 Key 16 Scene 14 Key 17 Scene 15 Key 18 Light zone 1 up Key 19 Light zone 1 down Key 20 Light zone 2 up Key 21 Light zone 2 down Key 22 Light zone 3 up Key 23 Light zone 3 down Key 24 Light zone 4 up Key 25 Lig...

Страница 89: ...ight Zone 2 Down Key 45 Slave 1 Light Zone 3 Up Key 46 Slave 1 Light Zone 3 Down Key 47 Slave 1 Light Zone 4 Up Key 48 Slave 1 Light Zone 4 Down Key 49 Slave 1 Light Zone 5 Up Key 50 Slave 1 Light Zone 5 Down Key 51 Slave 1 Light Zone 6 Up Key 52 Slave 1 Light Zone 6 Down Key 53 Slave 2 Light Zone 1 Up Key 54 Slave 2 Light Zone 1 Down Key 55 Slave 2 Light Zone 2 Up Key 56 Slave 2 Light Zone 2 Down...

Страница 90: ...days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from Crestron or an authorized Crestron dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any Crestron shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it ...

Страница 91: ...Crestron CLS C6 C6M CLSI C6 C6M iLux Integrated Lighting System Operations Guide DOC 6347E iLux Integrated Lighting System CLS C6 C6M CLSI C6 C6M 87 This page is intentionally left blank ...

Страница 92: ...Crestron Electronics Inc Operations Guide DOC 6347E 15 Volvo Drive Rockleigh NJ 07647 2012613 Tel 888 CRESTRON 11 12 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Отзывы: