63
ALL = ALL Light zones
Reply packet
[ILUX] LZ [X|ALL] LVL [LEVEL1] [….] [LEVEL6]
LEVEL x = 0 - 100 (for light zone 1 through 6)
Light Zone Lower or Raise Command
The following command is used to lower or raise the light zone control. Internal fade
time is used if fade time is not entered or if command is for slave iluxes:
Syntax:
[ILUX] LZ [X|ALL] [UP|DN] [FADETIME]
X = 1 - 6 light zone
ALL = All Light zones
UP = Raise light level
DN = Lower light level
FADETIME = 0 - 594000 in 0.01 second steps (e.g. 100 = 1 seconds)
Light Zone Stop Command
The following command is used to stop the light zone control:
Syntax: [ILUX] LZ [X|ALL] [STOP]
X = 1 - 6 light zone
ALL = All Light zones
STOP = Stop light level
Light Zone Toggle Command
The following command is used to toggle the light zone. Internal fade time is used if
fade time is not entered:
Syntax: [ILUX] LZ [X|ALL] TOG [FADETIME]
X = 1 - 6 light zone
ALL = All light zones
FADETIME = 0 - 594000 in 0.01 second steps (e.g. 100 = 1 seconds)
Light Zone Programming
Commands
Light zone Lower Limit Command
The following command is used to get light zone min limit. This command is not
supported for slave CLS-C6 controllers:
Syntax:
M LZ [X|ALL] MIN ?
X = 1...6 light zone
ALL = All light zones
Reply packet
[ILUX] LZ [XX|ALL] MIN [LIMIT1] [….] [LIMIT6]
LIMITx = 0 - 100 (for light zone 1 through 6)