CLS-C6/C6M & CLSI-C6/C6M
iLux Integrated Lighting System
Operations Guide – DOC. 6347E
iLux Integrated Lighting System: CLS-C6/C6M & CLSI-C6/C6M
•
59
Serial Command String Format to Third Party Controllers.
ILUX CONTROLLER
COMMAND
PAR1…X
CARRIAGE
RETURN
LINE FEED
Refer to “iLux Controller
Code Table” which
starts below for a list of
available options.
Refer to “RS-232
Command Table”
which starts on the
following page which
provides a description
of available
commands and the
required syntax.
A list of available
variables that
can be entered
into the
command. The
brackets should
be removed
from the
command.
[Par1]
[……..]
[Parx]
0Dh
0Ah
Serial Command String Format From Third Party Controllers.
STATUS
NUM
CARRIAGE
RETURN
LINE FEED
Response packet type 1
This response packet is returned if command fails or is invalid
ERROR
X=Error
Code
0Dh
0Ah
Response Packet Type 2
This response packet is returned if command requires status or reply packet
from the controller
Response
Par1 - Parx 0Dh
0Ah
Response Packet Type 3
This response packet is returned if there was no packet error and a status or
reply packet response is not required
OK
0Dh
0Ah
iLux Controller Code Table
CONTROLLER
CODES
DESCRIPTION
M
Commands the iLux Master Controller
S1 - S8
Commands the iLux Slave Controller 1 through 8
When entering a command to control the iLux replace [ILUX] in the “RS-232
Command Table” with the specified controller code listed in the “iLux Controller
Code Table” above. Possible entries are: M, S1, S2, S3, S4, S5, S6, S7 or S8.
Refer to the following “RS-232 Command Table” for a list of possible commands
that can be sent to the iLux. Information contained within braces (e.g. [ILUX] or
[X|ALL]) should be replaced with the appropriate command minus the braces. To
turn the echo command on for a master controller ([ILUX] ECHO ON|OFF) enter
“M ECHO ON”.
When a lighting load is declared as unaffected in iLux Designer the text console
reports “—“ as the value.