Product Manual — Doc. 9219A
DM NVX® 4K60 4:2:0 Network AV Encoders and Decoders • 83
Configure Input Control as follows:
o
Delay: In the drop-down list, select the number of seconds that must pass before
the Input Control command can be sent after the Power On command is sent.
Values are 0 seconds, 3 seconds, 5 seconds, 7 seconds, 10 seconds, or 20 seconds.
The default setting is 5 seconds.
o
Command String: In the text box, enter a valid command string. The maximum
length is 128 characters.
NOTE:
If the format of the command is to be specified as Hex in the Format drop-
down list discussed below, the Hex command string must be entered as pairs of
characters separated by a space. Valid characters are 0-9, a-f, and A-F. An
example of a command string is as follows:
58 00 0D 0A
o
Terminator: In the drop-down list, select one of the following terminators to append
to the command:
n
None: No terminator (default setting)
n
CR: Carriage return
n
LF: Line feed
n
CR_LF: Carriage return followed by a line feed
o
Format: In the drop-down list, select Hex (hexadecimal) or ASCII. The default setting
is Hex.
Click the Test button to test the Input Control command.
To close the Edit Output pop-up dialog box, click the CANCEL button at the bottom of the