Product Manual — Doc. 9219A
DM NVX® 4K60 4:2:0 Network AV Encoders and Decoders • 59
l
Manually add each encoder for subscription to the decoder as follows:
1. Click the Add Stream button. The Manual Subscription pop-up dialog box opens.
Manual Subscription Pop-Up Dialog Box
2. Enter the RTSP address and name of the encoder, and then click OK.
The encoder is added to the Subscribed Streams table, which shows the number,
device name, stream details, and bit rate of the subscribed stream. If a stream has
been started, the Stream Details column displays the RTSP address of the encoder.
If the stream has not been started, the Stream Details column indicates Stream not
started.
NOTE:
Subscribed encoders can be reordered in the list. To do so, click the Move Up
or Move Down icon in the Reorder column until the encoder appears in the desired
location in the list.
l
Load one or more subscription lists (*.xml) from a computer as follows:
NOTE:
The default filename of the subscription list is subscription.xml.
1. Click the Load Subscriptions button. The File Upload pop-up dialog box opens.
2. Click Browse. File Explorer opens.
3. Navigate to the desired file, select the file, and then click Open.
4. In the File Upload dialog box, click the Load button. When the file upload process is
complete, the File upload is complete message appears.
5. Click OK to close the dialog box.
l
Subscribe one or more encoders listed in the Available Streams table (refer to
for information).
Each subscribed encoder is added to the Subscribed Streams table.
If desired, save the subscribed encoders to a file by clicking the Save Subscriptions button.