8.
Common Causes of Test Failure
Once the testing has finished, all the errors will be listed on the screen. Usually, the error message is self-
explanatory. If you need detailed information, the test log files can be found in
/home/user/Desktop/masterFIP_log/fmcmasterfip.
Common problems with software setup
Please refer to the following paragraphs regarding issues that might affect each test.
USB calibration box not detected:
Verify that the USB cable is well connected between the PC and the box itself.
Verify with lsmod that the cp210x driver is mounted in the kernel.
Make sure you are using the Ubuntu version 14.04.00 LTS.
SPEC board with FMC masterFIP was not detected
Verify that the SPEC board is well connected to the PCIe port and the Pwr LED is ON.
Verify with lsmod that the SPEC and FMC drivers were properly mounted in the kernel.