![Creotech FMC masterFIP Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/creotech/fmc-masterfip/fmc-masterfip_user-manual_2682742016.webp)
- 15 -
7.
Testing Procedure
Place the ESD strap on your wrist.
Put the barcode sticker on the Bottom side of the FMC
masterFIP under test, in the position indicated with the white
square.
Mount the FMC masterFIP under-test on the SPEC board.
Connect the FMC masterFIP with the USB relay box and the nanoFIPdiag using the provided cables, as
in Figure 7. Note that the nanoFIPdiag speed version should match the masterFIP speed version.
Connecting Dsub9-LEMO cable:
o
connect the Dsub9 plug to the nanoFIPdDiag
o
connect the Positive LEMO plug to CH5 of the USB Relay Box
o
connect the Negative LEMO plug to CH3 of the USB Relay Box
Connecting miniDsub9-LEMO cable:
o
connect the miniDsub9 plug to the FMC masterFIP
o
connect the Positive LEMO plug to AWG IN of the USB Relay Box
o
connect the Negative LEMO plug to SYNC of the USB Relay Box
Connecting LEMO-LEMO cable:
o
connect CH1 of the USB Relay Box to the Trigger port of the FMC masterFIP