![Creotech FMC masterFIP Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/creotech/fmc-masterfip/fmc-masterfip_user-manual_2682742017.webp)
- 16 -
Switch ON the computer.
Verify that the “Pwr” LED on the SPEC board is ON. This
will confirm that the SPEC board is properly plugged.
If the LED is OFF there is a problem with the power
supply lines.
After the computer has finished with the booting procedure:
Start the test by double clicking “PTSmasterFIP” icon
on the desktop.
New terminal window will appear.
When asked, type the password: “baraka” and [ENTER]
The program asks for the barcode of the board.
Check that the cursor is on the terminal, press the
button/trigger on the barcode reader.
The code will appear on the terminal. Press [
ENTER
].
The program will ask for a second barcode, in case the
manufacturer has a different serial number system.
Scan the second barcode and press [
ENTER
], or if there is
none, just press [
ENTER
].
The program will automatically execute tests 00 to 05.
Tests 00 and 01 ask for the user‘s intervention.
Test 00 will ask the operator to verify the FMC
masterFIP speed version by visually checking which of
R47, R48, R52, R53 resistors is mount.
Test 01 will ask the operator to verify if LED’s of FMC
masterFIP front panel are blinking one-by-one.
At the end the operator is informed of the results of all the tests
and is asked if he wants to repeat the whole process.
If no error has occurred, type [
n
] and then [
ENTER
].
In case of error, you could repeat the tests once by
typing [
y
] and [
ENTER
].
When prompted to switch off computer:
Type [
y
] and confirm with [
ENTER
].