Stagehand Pro 3 Reference Manual, 11-20
Page 35 of 56
o
Press the
SET
button to accept the new value.
●
Restart the VFD by either cycling power to the Stagehand, or by pressing the Emergency Stop
button on the Showstopper and release it. Activating the Emergency Stop circuit will remove
power from the VFD.
●
Set the following parameters on the VFD keypad using the same process outlined above:
o
Set Parameter 9 equal to the rated current of the motor. (14A for 5hp)
o
Set Parameter 71 equal to 3. This is the setting for a general purpose motor.
o
Set Parameter 81 equal to the number of motor poles appropriate for the base rpm of
the motor (2 for 3600 rpm, 4 for 1800 rpm, 6 for 1200 rpm).
(4-pole motors are most
common)
o
Set Parameter 83 equal to the rated voltage of the motor.
(230V is standard)
o
Set Parameter 96 equal to 1. This will execute auto-tuning without moving the motor.
●
Press the
MODE
button until the keypad displays a 1 without flashing. You will need to press
the mode button thrice.
●
Press and hold the
Brake Test
button.
Содержание Stagehand Pro 3
Страница 1: ...Copyright 2020 Creative Conners Inc STAGEHAND PRO 3 REFERENCE MANUAL 1 1...
Страница 2: ...Stagehand Pro 3 Reference Manual 11 20 Index...
Страница 21: ...Stagehand Pro 3 Reference Manual 11 20 Page 15 of 56 Single encoder Dual encoders...
Страница 22: ...Stagehand Pro 3 Reference Manual 11 20 Page 16 of 56 Ethernet...
Страница 29: ...Stagehand Pro 3 Reference Manual 11 20 Page 23 of 56...
Страница 30: ...Stagehand Pro 3 Reference Manual 11 20 Page 24 of 56...
Страница 53: ...Stagehand Pro 3 Reference Manual 11 20 Page 47 of 56 SPECIFICATIONS Physical Specifications...
Страница 60: ...Stagehand Pro 3 Reference Manual 11 20 Page 54 of 56 PLC Ladder Logic...
Страница 61: ...Stagehand Pro 3 Reference Manual 11 20 Page 55 of 56...
Страница 63: ...Stagehand Pro 3 Reference Manual 11 20 Page 57 of 56...