Page 8 of 62
Protect the power supply cord during transportation and use. Periodically inspect the power supply cord for
damage. If the cord or plug is worn or damaged, it must be replaced with a power supply cord of the same type,
size and specification as originally provided with the Machine
.
DO
NOT USE THE VENDING MACHINE UNTIL THE WORN OR DAMAGED CORD IS REPLACED.
Prior to Initial Power Up
Open the Service Door on the right side using the Key provided in the coin return cup, or if shipped with a locking
clip, remove the clip and install the lock. Ensure there is no power to the AC Distribution Box. On Venders with a
main power switch on the AC Distribution Box the switch needs to be in the OFF position. On Venders with a main
power quick disconnect plug on the AC Distribution Box the quick disconnect plug needs to be unplugged. Check
that all connectors are firmly seated on the Vending Machine Control Board (VMC) and at the various Cabinet
Control Board Peripherals:
Cabinet Control Environmental Board
o
Refrigeration control
o
Lighting control
Cabinet Control Port Board
o
Port motor
o
Port product sensor
Cabinet Control Cup Board
o
Cup motor
o
Cup product sensor
Cabinet Control X Motor Board
Cabinet Control Y Motor Board
Retrieve the main power plug from the hole in the rear of the Vender and plug the cord in a properly grounded
120VAC, 15 Amp receptacle (U.S. and Canada).
Open the Service Door and apply power to the AC Distribution Box (if equipped with a Bill Acceptor, the Acceptor
should cycle twice). The Display on the Service Door will briefly show the software version in use as “Software
###.## (i.e. 006rxx) followed by the model number followed by No Errors. When the Service Door is closed the
Display will show “Ice Cold COCA-COLA”, the current price followed by the current temperature being reported to
the VMC the LED Light Assemblies should be lit and the cooling unit should start. If the Display shows “No sales
available”, or the cooling unit fails to start, refer to the TROUBLESHOOTING SECTION beginning on page 30 of this
guide.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY SUBJECT THE USER TO
THE RISK OF INJURY OR ELECTRICAL SHOCK WHICH CAN BE SERIOUS OR FATAL.
PERIODICALLY INSPECT THE POWER SUPPLY CORD FOR DAMAGE. IF THE CORD
BECOMES DAMAGED IT MUST BE REPLACED WITH THE SAME SIZE AND TYPE
CORD. CONTACT CRANE MERCHANDISING SYSTEMS FOR ASSISTANCE.