Cabinet Control Boards Green Status Light
Example - Cabinet Control Cup Board Status Light
Each of the 5 Cabinet Control Boards has a Green Status Light. A fast blinking Green status light (on and off 7
times per second) indicates that the Cabinet Control Board is receiving communication from the VMC and
sending a response. Note: Just because a response is being sent to the VMC doesn’t necessarily mean the VMC is
receiving it. There could be some defect that prevents the Cabinet Control Board response from reaching the
VMC. A Green Status Light On solid indicates the Cabinet Control Board has power but is not receiving
communication from the VMC, indicating there is a Cabinet Control Board, VMC, or harness connection
problem. No status light indicates the peripheral Cabinet Control Board is not receiving 5VDC or Communication.
Refer to troubleshooting for steps to determine possible cause.
Peripheral Cabinet Control Boards Green Status Light provide additional various lighting patters used to indicate
the status of the individual peripheral Cabinet Control Boards. They include:
Power on / Reset
– a slow brightening and then slow diming of the Green status light that takes 3 to 5 seconds
to complete. This happens once each time the Board is powered on and/or reset. If the Green status light
slowly brightens and dims continuously indicates the software was not loaded properly.
Heartbeat
– a heartbeat of the Green status light starts right after the “Power on / reset” indication and
continues until the peripheral first receives a message from the VMC. Once a message is received from the VMC
the heartbeat will not be shown again. Note: on a New Electronics Platform BevMax 4 Classic Machine, the
heartbeat is almost never actually seen because the VMC starts talking to the peripheral Cabinet Control Boards
within a few seconds of powering on.
Fast blinking
– a fast blinking Green status light (on and off approximately 7 times per second) indicates that
the peripheral Cabinet Control Board is receiving communication from the VMC and sending a response. Note:
Just because a response is being sent to the VMC doesn’t necessarily mean the VMC is receiving it. There could
be some defect that prevents the peripheral Cabinet Control Board response from reaching the VMC.
The following are some failure modes you may experience with the New Electronics Platform BevMax 4 Classic
Machine and the troubleshooting steps to identify and resolve the issue using the VMC Diagnostic Lights.
No Power to the Vender
1.
If the Vending Machine does not have power, check the following:
a.
The Vender Power Supply Cord is plugged into the electrical outlet.
b.
The Power Supply Cord GFCI is not tripped (Domestic Venders).
c.
The Power Supply Cord is plugged into the AC Distribution Box.
d.
The AC Distribution Box Lighted On/Off Switch is in the On position.
e.
The AC Distribution Box Lighted On/Off switch is illuminated green.
2.
Upon completing A through D, if the AC Distribution Box Lighted On/Off Switch is not illuminated green,
check the outlet voltage for required AC voltage.
a.
If outlet voltage is good, change the AC Distribution Box.
Green Status Light