3. Installation Preparation.

ON

OFF

ON

OFF

4. Hanging Bracket Installation.

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to the 
OFF position. 

WARNING: 

Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be sure the 

box is securely attached to the building structure and can 
support the full weight of the fan. Ensure it is clearly marked 
"Suitable for Fan Support." If not, it must be replaced with an 
approved outlet box. Failure to do so can result in serious 
injury.

CAUTION

: Be sure outlet box is grounded and that a ground 

wire (

GREEN

 or bare) is present.

Install hanging bracket to outlet box using original screws, 
spring washers and flat washers provided with new or 
original outlet box.

If installing on a vaulted ceiling, face 

opening of hanging bracket towards high point of ceiling. 

Arrange electrical wiring around the back of the hanging 
bracket and away from the bracket opening.

*Note

: It is very important that you use the proper hardware 

when installing the hanging bracket as this will support the 
fan. 

hanging bracket

spring washers

outlet box screws

flat washers

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

downrod

installation

flushmount

installation

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 7 feet (2.13m) from the floor and 
30in. (76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 400 square 
feet (37.2 square meters).

7 feet

(2.13 m) (76 cm)

30 

inches

blade edge

12f

t.

 - 20f

t.

12ft. - 20ft.

(3.66m - 6.1m)

(3.66m - 6.1m)

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling. The 
hanging length can be extended by purchasing a 
longer downrod (0.5in. /1.27cm diameter). Other 
installation, such as 

flushmount

, is 

NOT

 available 

for this fan.

NOTE

: Do not install anti-sway adapter if you will 

be using this fan on a sloped or vaulted ceiling.

Vaulted ceiling 
angle is not to 
exceed 25 degrees.

Содержание Union UN52-LED

Страница 1: ...ght Kit Assembly pg 8 Handheld Remote Control Assembly pg 9 Automated Learning Process Activating Code pg 10 Remote Wall Control Operation pg 11 Testing Your Fan pg 11 Troubleshooting pg 12 Warranty p...

Страница 2: ...supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of personal injury electrical shock or death 5 Electrical diagrams are for reference only 6 After instal...

Страница 3: ...e c downrod and hanging ball 1 piece d motor housing 1 piece e downrod accessory 1 piece f yoke cover 1 piece g weatherproof hanging ball cover 1 piece h anti sway adapter in hardware pack 1 piece i c...

Страница 4: ...und the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan hangin...

Страница 5: ...wnrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nuts securely Refer to diagram 2 Locate canopy cover a...

Страница 6: ...cable slips the loop must be adjusted tighter Extra cable slack can be left in ceiling area Thread safety cable and wires through hanging ball then slide hanging ball over downrod the top of the downr...

Страница 7: ...ial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communic...

Страница 8: ...h washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat procedure for each remaining blade Note Tighten blade attachment screws twice a year hanging bracket ca...

Страница 9: ...kit Be sure molex connections snap together securely Note If you will NOT be using the light kit do NOT connect the plugs Carefully arrange wiring within the back of LED light kit Align slotted holes...

Страница 10: ...o the OFF position ON Refer to diagram 2 Align holes in wall control with posts located on inside of TOP part of remote control cover and press together firmly Place wall control into BOTTOM part of r...

Страница 11: ...light blinks twice Test the light and fan functions to confirm the learning process is complete see Section 13 on the following page Select a faceplate almond or white and press firmly onto front of...

Страница 12: ...all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan functions refer to Troubleshooting section to solve any issue...

Страница 13: ...For parts and information please refer to Parts Inventory on page 2 Craftmade Customer Support 1 800 486 4892 www craftmade com CRAFTMADE LIFETIME LIMITED WARRANTY CRAFTMADE warrants this fan to the o...

Страница 14: ...Instalaci n del juego de luz P g 8 Ensamblaje del control remoto de mano P g 9 Proceso de aprendizaje autom tico Activar el c digo P g 10 Funcionamiento del control remoto de pared P g 11 Verificaci...

Страница 15: ...ilador en un lugar MOJADO hay que conectar el ventilador a un circuito de alimentaci n que est protegido por un Interruptor de Circuito de Falla de Tierra GFCI por sus siglas en ingl s para reducir el...

Страница 16: ...de vidrio 1 unidad m control de pared 2 unidades n cubierta del control remoto 1 unidad o placa 1 unidad p tapa 3 unidades q aspa 4 unidades r paquetes de art culos de ferreter a p gina 2 Abrir el emp...

Страница 17: ...la parte de atr s del soporte y lejos de la abertura del soporte Nota es muy importante usar los art culos de ferreter a correctos al instalar el soporte de montaje puesto que sirve para sostener el v...

Страница 18: ...en exceso por la parte de arriba del tubo Referirse al diagrama 2 Enroscar el tubo en el cuello del bastidor del motor hasta alinearse los agujeros para el perno y la clavija en el tubo con los del c...

Страница 19: ...ra Poner el cable a prueba jalando con un alicate la parte suelta en la punta del cable Si el cable se desliza o se reduce el bucle del cable por donde pasa el tornillo hay que ajustar el bucle de nue...

Страница 20: ...radiar energ a de radiofrecuencia y si no se instala y no se usa seg n las instrucciones puede causar interferencia adversa en la radiocomunicaci n Sin embargo no hay ninguna garant a de que no habr i...

Страница 21: ...Introducir 3 tornillos para fijar el aspa junto con las arandelas con los dedos primero y luego apretarlos bien con un destornillador de estrella Phillips Repetir el procedimiento con las dem s aspas...

Страница 22: ...urarse de que las conexiones tipo molex se cierren bien con un clic NOTA Si no va a utilizar el juego de luz NO conectar los enchufes Cuidadosamente arregle los cables detr s del juego de luz LED Alin...

Страница 23: ...fijamente Colocar el control de pared dentro de la parte INFERIOR de la cubierta del control remoto alineando los postes en la parte superior de la cubierta del control remoto con los agujeros para l...

Страница 24: ...or para confirmar que se ha terminado el proceso de aprendizaje ver la secci n 13 en la p gina siguiente Escoger una tapa color almendra o blanco y apretarla firmemente en la parte delantera del contr...

Страница 25: ...el control de pared instalaci n opcional localizando el interruptor corredero de APAGADO y ENCENDIDO en el control de pared luego ponerlo en posici n de ENCENDIDO ON Poner a prueba la luz y la funci n...

Страница 26: ...en el los tornillo s de fijaci n en el cuello del bastidor del motor 3 Averiguar que se apret bien el tornillo de fijaci n en la bola que sirve para colgar Para piezas o informaci n referirse al Inven...

Отзывы: