page 6

6. Wiring.

7. Canopy Assembly.

CAUTION

Be sure outlet box is properly grounded 

and that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. 
If you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to in the instructions below, please use a 
qualified electrician.

Note

Excess lead wire length from the fan can be cut 

to the desired length and then stripped.

WARNING

:  If using this fan in a 

WET

 or 

DAMP

 

location, this fan must be connected to a supply 
circuit that is protected by a Ground Fault Circuit 
Interrupter (GFCI) to reduce the risk of personal 
injury, electrical shock or death.

When fan is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK

 and 

BLUE

 wires from fan to 

BLACK

 

wire from ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from 

fan to 

BARE

/

GREEN

 wire from ceiling with wire 

connector provided.

If you intend to control the fan light with a separate 
light switch connect 

BLUE

 wire from fan  to the 

BLACK

 (or 

RED) 

supply from the independent 

switch.

* Wrap each wire connector separately with 
electrical tape as an extra safety measure.

This fan is remote control adaptable (remote 
control sold separately). 

Note

: Only remote controls approved for 

WET

 

locations can be used with this fan.

Temporarily raise canopy to hanging bracket to determine 
which 2 screws in hanging bracket align with 

slotted

 holes 

in canopy, and then lower canopy and 

partially loosen

 

these 2 screws. 

Remove

 the 

other

 2 screws and set aside.

Now, lift canopy to hanging bracket again, aligning slotted 
holes in canopy with loosened screws in hanging bracket. 
Twist canopy to lock. Re-insert the other 2 screws and 
secure all screws with a Phillips screwdriver.

Slide canopy cover up to canopy, aligning rounded part of 
slotted holes in canopy cover with screw heads in bottom 
of canopy.  Turn canopy cover to right (clockwise) until it 
stops.

black

black

white

white

blue

black supply wire

white supply wire

from ceiling

from fan

ground 
(green or bare)

*

ground

 (green

or bare)

canopy

hanging bracket

slotted

 holes

canopy cover

Содержание LAP54SSDW5

Страница 1: ...leshooting pg 10 Warranty pg 10 Parts Replacement pg 10 net weight of fan 31 57 lb 14 32 kg READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE PRINTED IN CHINA Installation Guide For model LAP54SSDW...

Страница 2: ...proper size wire connectors to use WARNING If using this fan in a WET or DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to r...

Страница 3: ...r installation and safety a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball 1 piece d motor housing 1 piece e yoke cover 1 piece f canopy cover in hardware pack 1 piece g weatherpr...

Страница 4: ...d ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important tha...

Страница 5: ...o diagram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously r...

Страница 6: ...loose end with pliers If the safety cable slips the loop must be adjusted tighter Extra cable slack can be left in ceiling area Thread safety cable and wires through hanging ball then slide hanging ba...

Страница 7: ...r from fan to BARE GREEN wire from ceiling with wire connector provided If you intend to control the fan light with a separate light switch connect BLUE wire from fan to the BLACK or RED supply from t...

Страница 8: ...square holes in the side of motor housing Align blade arm holes with motor screw holes and attach blade arm with blade arm screws lock washers Before securing screws permanently repeat procedure with...

Страница 9: ...Important When replacing bulbs please allow bulbs and glass shade to cool down before touching them Raise glass shade in order to guide pull chains through corresponding holes Align threaded rod on li...

Страница 10: ...e contacting Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in...

Страница 11: ...ectrical or water abuse results in causing the malfunction Deterioration of finishes or other parts due to time or exposure to salt air is specifically exempted under this warranty Neither Craftmade E...

Страница 12: ...nto del ventilador P g 9 Localizaci n de fallas P g 10 Garant a P g 10 Piezas de repuesto P g 10 peso neto del ventilador 14 32 kg 31 57 lb IMPRESO EN CHINA LEER ESTAS INSTRUCCIONES Y GUARDARLAS PARA...

Страница 13: ...r con un electricista para informarse sobre el tama o correcto de conectores para cable que se debe usar ADVERTENCIA Si va a utilizar este ventilador en un lugar MOJADO o HUMEDO hay que conectar el ve...

Страница 14: ...tubo y bola que sirve para colgar 1unidad d bastidor del motor 1 unidad e cubierta del cuello 1 unidad f tapa de la cubierta decorativa en paquete de art culos de ferreter a 1 unidad g cubierta a pru...

Страница 15: ...ado colocar el soporte de montaje con la abertura dirigida hacia la parte alta del techo Arreglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura del soporte...

Страница 16: ...ubo en el cuello del bastidor del motor hasta alinearse los agujeros para el perno y la clavija en el tubo con los del cuello asegurarse de que no se tuerzan los cables Volver a introducir el perno y...

Страница 17: ...que se detenga la bola en el soporte de montaje Girar la bola que sirve para colgar hasta que la ranura de la bola se alinee con la parte saliente del soporte de montaje ADVERTENCIA El no alinear la r...

Страница 18: ...cable AZUL del ventilador al conductor NEGRO o ROJO que corresponde al interruptor independiente 7 Colocaci n de la cubierta decorativa Como una medida de seguridad adicional envolver cada conector p...

Страница 19: ...ijar las aspas junto con las arandelas con los dedos primero y luego apretar los tornillos bien con un destornillador de estrella Phillips Repetir el procedimiento con las dem s aspas Sacar los tornil...

Страница 20: ...en la pantalla y las bombillas antes de tocarlas Subir la pantalla de vidrio para pasar las cadenas de encendido por los agujeros correspondientes en la pantalla de vidrio Alinear la varilla roscada...

Страница 21: ...resolver cualquier asunto antes de comunicarse con el Servicio al cliente Apagar el ventilador completamente antes de mover el interruptor de reversa Regularlo para que se circule bien el aire dependi...

Страница 22: ...rioro en el acabado u otras partes debido al tiempo o exposici n al aire marino bajo esta garant a Ni Craftmade Ellington ni el fabricante se har n responsables por lo que pasa por una instalaci n ina...

Отзывы: