10. Light Kit Assembly. 

IMPORTANT: 

Any light kit purchased for use 

with this fan 

MUST be APPROVED for WET 

LOCATIONS or OUTDOOR USE.

Remove 1 screw from post located in middle 
of switch housing plate and partially loosen 
the other 2 screws on the other 2 posts. 
Connect male plug from motor housing to 
female plug from light kit fitter. Connect 
male plug (small) from the switch housing 
plate to female plug (small) from the light kit 
fitter. Make sure plugs connect tightly. Align 
slotted holes in light kit fitter with loosened 
screws in switch housing plate. Twist light kit 
fitter to lock. Re-insert screw  previously 
removed and tighten all 3 screws securely.

Remove finial, finial plate and threaded 
washer from light kit fitter. 

Install 3 candelabra base 40 watt max. bulbs 
(included).

Important

: When replacing bulbs, please 

allow bulbs and glass shade to cool down 
before touching them.

Raise glass shade in order to guide pull 
chains through corresponding holes. Align 
threaded rod on light kit fitter with hole in 
middle of glass shade and push up gently 
allowing threaded rod to come through hole. 
(

Be sure pull chain for fan operation does not 

rub against bulb during operation.

) Secure 

glass shade with threaded washer. 

Note: 

Do 

NOT overtighten threaded washer as glass 
may crack or break.  Align hole in center of 
finial plate with threaded rod, allowing pull 
chains to come through appropriate holes in 
finial plate, and push up. Thread center pull 
chain through hole in finial and re-attach 
finial. 

Note:

 

Do NOT overtighten finial as glass 

may crack or break.

 

finial

finial plate

threaded washer

male plug (large)

female plug (large)

male plug (small)

female plug (small)

light kit fitter

finial plate 

threaded washer

finial 

switch 
housing 
plate

bulb

pull chains

glass shade

post 

Содержание LAP54SSDW5

Страница 1: ...leshooting pg 10 Warranty pg 10 Parts Replacement pg 10 net weight of fan 31 57 lb 14 32 kg READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE PRINTED IN CHINA Installation Guide For model LAP54SSDW...

Страница 2: ...proper size wire connectors to use WARNING If using this fan in a WET or DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to r...

Страница 3: ...r installation and safety a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball 1 piece d motor housing 1 piece e yoke cover 1 piece f canopy cover in hardware pack 1 piece g weatherpr...

Страница 4: ...d ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important tha...

Страница 5: ...o diagram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously r...

Страница 6: ...loose end with pliers If the safety cable slips the loop must be adjusted tighter Extra cable slack can be left in ceiling area Thread safety cable and wires through hanging ball then slide hanging ba...

Страница 7: ...r from fan to BARE GREEN wire from ceiling with wire connector provided If you intend to control the fan light with a separate light switch connect BLUE wire from fan to the BLACK or RED supply from t...

Страница 8: ...square holes in the side of motor housing Align blade arm holes with motor screw holes and attach blade arm with blade arm screws lock washers Before securing screws permanently repeat procedure with...

Страница 9: ...Important When replacing bulbs please allow bulbs and glass shade to cool down before touching them Raise glass shade in order to guide pull chains through corresponding holes Align threaded rod on li...

Страница 10: ...e contacting Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in...

Страница 11: ...ectrical or water abuse results in causing the malfunction Deterioration of finishes or other parts due to time or exposure to salt air is specifically exempted under this warranty Neither Craftmade E...

Страница 12: ...nto del ventilador P g 9 Localizaci n de fallas P g 10 Garant a P g 10 Piezas de repuesto P g 10 peso neto del ventilador 14 32 kg 31 57 lb IMPRESO EN CHINA LEER ESTAS INSTRUCCIONES Y GUARDARLAS PARA...

Страница 13: ...r con un electricista para informarse sobre el tama o correcto de conectores para cable que se debe usar ADVERTENCIA Si va a utilizar este ventilador en un lugar MOJADO o HUMEDO hay que conectar el ve...

Страница 14: ...tubo y bola que sirve para colgar 1unidad d bastidor del motor 1 unidad e cubierta del cuello 1 unidad f tapa de la cubierta decorativa en paquete de art culos de ferreter a 1 unidad g cubierta a pru...

Страница 15: ...ado colocar el soporte de montaje con la abertura dirigida hacia la parte alta del techo Arreglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura del soporte...

Страница 16: ...ubo en el cuello del bastidor del motor hasta alinearse los agujeros para el perno y la clavija en el tubo con los del cuello asegurarse de que no se tuerzan los cables Volver a introducir el perno y...

Страница 17: ...que se detenga la bola en el soporte de montaje Girar la bola que sirve para colgar hasta que la ranura de la bola se alinee con la parte saliente del soporte de montaje ADVERTENCIA El no alinear la r...

Страница 18: ...cable AZUL del ventilador al conductor NEGRO o ROJO que corresponde al interruptor independiente 7 Colocaci n de la cubierta decorativa Como una medida de seguridad adicional envolver cada conector p...

Страница 19: ...ijar las aspas junto con las arandelas con los dedos primero y luego apretar los tornillos bien con un destornillador de estrella Phillips Repetir el procedimiento con las dem s aspas Sacar los tornil...

Страница 20: ...en la pantalla y las bombillas antes de tocarlas Subir la pantalla de vidrio para pasar las cadenas de encendido por los agujeros correspondientes en la pantalla de vidrio Alinear la varilla roscada...

Страница 21: ...resolver cualquier asunto antes de comunicarse con el Servicio al cliente Apagar el ventilador completamente antes de mover el interruptor de reversa Regularlo para que se circule bien el aire dependi...

Страница 22: ...rioro en el acabado u otras partes debido al tiempo o exposici n al aire marino bajo esta garant a Ni Craftmade Ellington ni el fabricante se har n responsables por lo que pasa por una instalaci n ina...

Отзывы: