Super Shot 125 Diesel Melter Part Manual
Chapter 8 Troubleshooting (43600, 43800 and 45500)
©2017 by Crafco, Inc. All Rights Reserved………………...……………Troubleshooting (43600, 43800, and 45500) 8-31
Step
Possible Cause
If . . .
4b
Is there 12 Vdc between the trigger red wire
going toward the hose and a nearby ground
source?
(Make sure the wand trigger is pulled during this
Step.)
• Yes, go to Step 4c.
• No, go to Step 5.
4c
Is there 12 Vdc between the trigger green wire
coming from the control box and a nearby
ground source?
(Make sure the wand trigger is pulled during this
Step.)
• Yes, go to Step 6.
• No, check for a broken wire or poor wire
crimp on the green trigger wire going to
the control box.
5
Disconnected the five pin connector between the
hose and wand. Refer to
Is there continuity on the wand connector
between red trigger "C" post and red trigger "B"
post while the wand trigger is pulled?
• Yes, go to Step 5a.
• No, call Crafco, Inc.and request an
RA # so you can send your wand
back for repair.
5a
Disconnect the two red trigger wires in the
junction box going toward the hose. Move the
wand end of the hose next to the junction box.
Is there continuity on the hose connector "C"
socket and only one red trigger in the junction
box?
(Check both red trigger wires in the junction box
one at a time.)
• Yes, go to Step 5b.
• No, recheck the hose connector "C"
socket to the other red trigger wire in
the junction box. (You want to see
continuity between only one red trigger
wire and the "C" socket.)
• Still no or continuity to both red trigger
wire, then call Crafco, Inc. and request
an RA# so you can send your hose
back for repair.
5b
Is there continuity on the hose connector "B"
socket and red trigger in the junction box?
• Yes, call Crafco, Inc. and speak to a
service technician, you should have
found the problem.
• No, recheck the hose connector "B"
socket to the other red trigger wire in
the junction box. (You want to see
continuity between only one red trigger
wire and the "B" socket.)
• Still no or continuity to both red trigger
wire, then call Crafco, Inc. and request
an RA# so you can send your hose
back for repair.
Table 8-27 Pump Electrical Troubleshooting (continued)
Содержание SUPER SHOT 125
Страница 1: ...Parts Manual 26631 Revision D SUPER SHOT 125 DIESEL MELTER ALL MODELS...
Страница 4: ...Super Shot 125 Diesel Melter PN 43600 Super Shot 125 Diesel Melter with Compressor 100 CFM PN 47400...
Страница 20: ......
Страница 24: ......
Страница 28: ......
Страница 64: ......
Страница 68: ......
Страница 224: ......
Страница 228: ......
Страница 229: ......
Страница 230: ...2017 Crafco Inc...