Super Shot 125 Diesel Melter Part Manual
Chapter 9 Troubleshooting (47400)
©2017 by Crafco, Inc. All Rights Reserved………………...…………………………………Troubleshooting (47400) 9-6
Step
Possible Cause
If . . .
14
Is there 12Vdc between top terminal of circuit
breaker (red wire) and nearby ground source
(black wire)?
•
Yes, check for loose or broken wires
between top terminal of circuit breaker and
bottom terminal (red wire) of power switch.
•
No, go to Step 14a.
14a
Is there 12Vdc between bottom terminal of
circuit breaker (red wire) and nearby ground
source (black wire)?
•
Yes, replace circuit breaker.
•
No, go to Step 15.
15
Check connections and condition of red
battery cable.
•
Yes, there should be 12Vdc at all previous
steps.
•
No, replace battery cable.
Table 9-6 Burner Electrical Troubleshooting (continued)