Super Shot 125 Diesel Melter Part Manual
Chapter 5 Operating Instructions
©2017 by Crafco, Inc. All Rights Reserved………………..…………………………………..….Operating Instructions 5-19
Step
Action
6
Locate the shot size control box (It will be near the main control box). Inside
this box is a knob that controls how long the pump stays running each time you
pull the trigger (1/4 to 5 seconds). Crafco recommends setting the dial between
¼ and ½ for the shot size.
7
Use the pump speed control to make the final adjustment to the size of the shot
needed for the job.
WARNING
8
While in the “MARKER” mode the material pump turns for the duration of time
set by the shot size dial. Once the wand trigger is pulled the pump will not stop
until the time expires even if the wand trigger is released.
9
When the material flow stops the system is ready to be started again, release
the wand trigger and pull the wand trigger when you are ready for the next
shot.
10
At the end of the day use the pump reverse toggle switch located at the rear of
the machine. Reverse the material pump for at least 30 seconds.
Note:
The pump mode does not change the way the pump reverse works.
Table 5-16 Shot Timer Option (continued)