39
9. Fan Replacement
Disconnect power supply to the
FX134A / FX1234 / FX3030
series.
Danger:
Only a qualified service technician should service this equipment. An
Electrical Shock hazard is present which could lead to severe injury or even death.
a. Front Panel Service Access: Please see Section 1 part 2
b. Locate fan in the compressor department.
c. Remove both screws holding fan in place.
d. Remove fan wires once fan is removed from back panel.
10. Refrigerant Identifier Replacement / Maintenance (FX1234, FX3030)
Disconnect power supply to the
FX1234 / FX3030
series.
Danger:
Only a qualified service technician should service this equipment. An Electrical Shock hazard is present which
could lead to severe injury or even death.
Danger- Avoid breathing refrigerant vapors and lubricant vapor or mist. Breathing high concentration levels may
cause heart arrhythmia, loss of consciousness, or even cause suffocation.
Caution- all hoses may contain liquid refrigerant under pressure. Contact with refrigerant may cause frostbite or other
related injuries. Wear proper personal protective equipment such as safety goggles and gloves. When disconnecting any
hose, please use extreme caution.
Remove both mounting screws and uplug fan wires