
37
7. DC Power Supply Replacement
Danger:
Only a qualified service technician should service this equipment. An Electrical Shock hazard is present
which could lead to severe injury or even death.
Disconnect power supply to the
FX134A / FX1234 / FX3030
Series.
a.
Front Panel Service Access: See Section 1 part 2
b.
Locate both power supplies in vacuum pump compartment of unit.
c.
Disconnect wires from selected power supply.
d.
Using a pair of needle nose pliers. Compress the nylon stand off one at a time to release PCB from standoffs.
15 watt power supply front one. The 65 watt power
supply is the back on.
To remove PCB from stand offs. Squeeze stand off
from flat side using a pair of needle nose pliers to
depress little clip and slide PCB corner off of stand off.
Содержание FX1234
Страница 1: ...1 FX Series Service Manual Models FX134 FX1234 FX3030 CPS AUTOMOTIVE RECOVER RECYCLE RECHARGE ...
Страница 14: ...14 FX3030 PUMP DOWN ...
Страница 15: ...15 Hose Flush High Voltage Compressor ...
Страница 47: ...47 1 FX134A FX1234 FX3030 Series Refrigeration Schematic ...
Страница 48: ...48 2 FX134A FX1234 FX3030 Series Electrical Schematic ...