21
5. Tank Weight Configuration
WARNING!!!!! ONLY CPS APPROVED SERVICE TECHNICIANS SHOULD PERFORM THIS
PROCEDURE. It is very important that the correct tank weights are entered. Failure to input the
correct information could lead to a dangerous condition on where the storage tank is overfilled.
OVERFILLED TANKS CAN EXPLODE.
The Models FX134A / FX1234 / FX3030 are shipped with a 50lb DOT storage tank (CRX400T).
.
Use only CPS approved storage tanks on the FX134A / FX1234 / FX3030 Series. If other than CPS
approved storage tank are use, they must meet the specific country’s safety regulations on
refrigerant storage.
The following is how to adjust the tank settings on the FX134A / FX1234 / FX3030 Series PCB:
a. Turn unit on and proceed to main menu, and select the gears icon on bottom of screen.
b. On next screen select the gears icon on the left side of screen.
c. Then select tank icon on next screen. Then select red circle icon on next screen, and enter password
ABBA1216
.
d.
The first screen you will enter tank weight. This is the T.W. stamped on tank.
e.
Then push green arrow to next screen and enter water capacity weight. This is the W.C. stamped on tank.
f.
Then push W for water capacity and preset amount of empty tank weight and max refrigerant will display.
g.
Push green arrow to lock in and continue back to main screen.
If you have any questions about the tank selection, please call 877-776-8486, and ask for technical support.
Содержание FX1234
Страница 1: ...1 FX Series Service Manual Models FX134 FX1234 FX3030 CPS AUTOMOTIVE RECOVER RECYCLE RECHARGE ...
Страница 14: ...14 FX3030 PUMP DOWN ...
Страница 15: ...15 Hose Flush High Voltage Compressor ...
Страница 47: ...47 1 FX134A FX1234 FX3030 Series Refrigeration Schematic ...
Страница 48: ...48 2 FX134A FX1234 FX3030 Series Electrical Schematic ...