31
1. PC Board and/or LCD Replacement
Danger: Only a qualified service technician should service this equipment. An Electrical Shock hazard is present which
could lead to severe injury or even death.
Disconnect power supply to the FX134A / FX1234 / FX3030.
.
Keep the PC Board free from static electricity. Static electricity can damage the microprocessor.
a.
Service Access: See Section 1 parts 2 & 3
b.
Remove all wire connection from Main PCB
c.
Remove four screws on PCB/LCD mounting bracket.
d.
Remove four outside screws on PCB to separate LCD and Main PCB
Remove four mounting screws, two on each each side.
Remove all four screws located in corners of PCB to
separate LCD and PCB
Содержание FX1234
Страница 1: ...1 FX Series Service Manual Models FX134 FX1234 FX3030 CPS AUTOMOTIVE RECOVER RECYCLE RECHARGE ...
Страница 14: ...14 FX3030 PUMP DOWN ...
Страница 15: ...15 Hose Flush High Voltage Compressor ...
Страница 47: ...47 1 FX134A FX1234 FX3030 Series Refrigeration Schematic ...