1018454-D
Page 21
STARTING PILOT PRO SYSTEM PER ANSI Z21.71
STEP 5.
Re-install the heater door on the front of the
housing, at the base.
STEP 3.
STEP 4.
Determine that the pilot is igniting and burning properly and that
main burner ignition is satisfactory by turning the thermostat
off and back on. Make this determination with the appliance
burner both cold and hot. Perform this step as many times as is
necessary to satisfy yourself that the automatic intermittent pilot
system is operating properly.
Sequence the appliance through at least three (3)
operating cycles.
!
Ensure Ignitor sparks only
against the hood of the pilot.
Ignitor should not spark against the flame sensor, brackets, heating
chamber, burner, etc. Adjust ignitor probe location if required.
- DO NOT
twist ignitor wire or break from ceramic base.
- DO NOT
use a broken ignitor.