1018454-D
Page 28
STEP 1.
This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the latest edition of
the National Electric Code, ANSI/NFPA No. 70.
In Canada, see the current Canadian Electrical
Code CSA C22.1.
STEP 2.
Set fan kit on top of the wall furnace front panel.
Using the back top edge of the fan kit cabinet as
a guide, mark a horizontal line across the wall.
Mark a small vertical line which aligns with the slot
located toward the rear of the fan kit casing.
STEP 3.
Using the four one inch screws provided, secure
the wall mounting bracket to wall 1/8” below the
horizontal line. Fan attachment bracket must be
up and threaded nut sert aligned with the small
vertical line.
Note: Anchors (not provided) may be required.
STEP 4.
Remove junction box and connect 115v power
supply in accordance with the wiring diagram.
Replace junction box.
STEP 5.
Set fan kit on top of wall furnace front panel. Slot
should align with the nut sert. Secure fan kit to
wall mounting bracket with thumb screw provided.
NOTE: This fan kit is to be installed after installation
of the wall furnace and with the wall furnace front
panel in place.
FIG. 13
THREADED
NUT SERT
SLOT
FAN
ATTACHMENT
BRACKET
WALL
MOUNTING
BRACKET
THUMB
SCREW
ONE INCH
SCREW (x
4)
WALL FURNACE
FRONT PANEL
FAN KIT
WIRING
DIAGRAM
JUNCTION
BOX
WFF81 - C WIRING SCHEMATIC
FIG. 14
115 VAC 60 HZ - LESS THAN 12 AMPS. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THIS APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH TYPE THERMOPLASTIC 105 DEGREE C WIRE OR ITS EQUIVALENT.
GROUND
BLACK
L1 BLACK
115 VAC
FAN SWITCH
GREEN GROUND WIRE
L2 WHITE
115 VAC
WHITE
BLACK
BLACK
BLACK
BLACK
WHITE
MOTOR
L1
BLACK
L2
WHITE
MODEL WFF81-C OPTIONAL FAN KIT - (Optional)