INSTALLATION MANUAL
SAFETY
5
Use an extension cord to connect the COVANA
cover to its power source. The cord may not be
properly grounded, and the connection is a shock
hazard. An extension cord may cause a voltage
drop, which would cause the motor to overheat.
CAUTION
Be sure to follow all instructions in this manual
and use only COVANA-approved accessories
and tools.
Do not roll the COVANA cover onto its side or
slide it on its side. This will damage the siding.
After removing any part, always place it in a safe
place on a clean and level surface to ensure
proper functionality.
All four posts of the COVANA cover must be
properly anchored to the foundation using the
anchoring holes located at the foot of each post.
The optional non-permanent mounting plates can
be used when anchoring is not possible, but
under strict condition. See
Non-permanent
mounting plates installatio
n section on Installation
Manual for further details.
This product mainly contains steel, plastic,
copper (Cu) and die-cast aluminum (Al). The
gearbox contains oil and other materials. Please
recycle them properly.
Both the up and down limit switches are pre-
adjusted at the factory. The down-limit switch
should never be re-adjusted. The up-limit switch
should be re-adjusted only to reduce the
maximum height of the cover to avoid possible
contact with its surroundings. Please refer to the
Limit Switch Adjustment
section in this manual
before making any adjustments. An improper
adjustment can result in damage to the drive
system and/or cover.
Avoiding the risk of electrocution
ELECTRICAL DANGER
Failure to comply with these instructions may
result in death by electrocution or serious injury.
Disconnect or turn off and secure all power
supplies before starting any intervention on the
COVANA cover.
A disconnect mean needs to be incorporated into
the fixed wiring at the time of installation. This
mean must be accessible to the user or service
technician to turn the power off for future
maintenance or repair.
Always have a licensed electrical contractor
perform any electrical maintenance or repairs on
the COVANA cover. The wiring must comply with
all applicable local electrical codes and
regulations.
The COVANA operator must be connected to a
circuit that is protected by a dedicated ground
fault circuit interrupter (GFCI) that complies with
all applicable local electrical codes and
regulations.
Install the COVANA cover in such a way that
drainage directs water away from the electrical
and base mechanical components.
Do not connect any auxiliary components to the
electrical system of the COVANA cover unless
they have been approved by COVANA.
Replace electrical components with original
components provided or approved by COVANA.
Ask your dealer for replacement parts.
To reduce the risk of electrical shock, replace all
damaged electrical cables immediately. Failure to
do so may result in death or serious personal
injury due to electrocution.
Do not bury any electrical cables. A buried cable
may result in death, or serious personal injury due
to electrocution if direct burial-type cable is not
used, or if improper digging occurs.
ELECTRICAL WARNING
To reduce the risk of electric shock, the green-
colored terminal or the terminal marked “g,” “gr,”
“ground,” “grounding” or with a
⏚
symbol that is
located inside the supply terminal box or
compartment must be connected to the
grounding means provided in the electric supply
service panel with a continuous copper wire
equivalent in size to the circuit conductors
supplying the equipment.
Two lugs marked “bonding lugs” are provided on
the external surface or on the inside of the supply
terminal box or compartment. To reduce the risk
of electric shock, connect the local common
bonding grid in the area of the COVANA cover.
Use terminals with an insulated or bare copper
conductor not smaller than No. 6 AWG (4.11
mm).
All field-installed metal components, such as
rails, ladders, drains or other similar hardware,
within 10 ft. (3 m) of the hot tub must be bonded
to the equipment grounding bus with copper
conductors no smaller than No. 6 AWG (4.11
mm). (NEC art. 680.)
Содержание OASIS
Страница 1: ...2019 Revision 0 2019 04 03 C A 232859 ...
Страница 44: ...44 TECHNICAL SPECIFICATIONS INSTALLATION MANUAL NOT TO SCALE Long side LS model Figure 87 ...
Страница 49: ...INSTALLATION MANUAL APPENDIX 49 APPENDIX ...
Страница 50: ...50 APPENDIX INSTALLATION MANUAL ...
Страница 51: ...INSTALLATION MANUAL APPENDIX 51 ...
Страница 52: ...52 APPENDIX INSTALLATION MANUAL ...
Страница 53: ...INSTALLATION MANUAL APPENDIX 53 ...
Страница 54: ...54 APPENDIX INSTALLATION MANUAL ...
Страница 55: ...INSTALLATION MANUAL APPENDIX 55 ...
Страница 56: ...56 APPENDIX INSTALLATION MANUAL ...
Страница 57: ...INSTALLATION MANUAL APPENDIX 57 ...
Страница 58: ...58 INSTALLATION MANUAL This page intentionally left blank see next page ...