52
INSTALLATION MANUAL
The cover lowers, but
does not rise.
The cam plate is
missing.
The key switch is
faulty.
Limit
switches
are
stuck.
Only a
certified electrician
can open the
operator and check for faulty up and down
limit switches.
Verify whether there is any corrosion on the
terminals. If yes, clean the terminals.
Open the key switch terminal and check for
faulty switches.
Verify if any wires are cut/pinched.
The contour seal
seems contaminated.
The
seal
has
accumulated mold.
Clean the affected areas with bleach and a
soft brush.
Cover no longer tilts
Brass shear pin in tilt
mechanism is broken.
Gas spring is weak.
Too much snow/ice on
cover.
Replace shear pin as per instructions.
Remove snow/ice.
If all previous attempts failed, contact your
local dealer.
Cover tilts but will not
return to flat position
when lowering
Gas spring is faulty
Pivot mechanism is
jammed
Replace pivot assembly gas springs.
If possible, manually pivot the cover to
vertical position by pulling down on front of
cover while lowering
– no more than 50 lbs
Call your local dealer
Содержание C-HOR
Страница 1: ...Revision 13 2018 04 23...
Страница 53: ...INSTALLATION MANUAL APPENDIX 53 APPENDIX...
Страница 54: ...54 APPENDIX INSTALLATION MANUAL Wiring diagram North America 60 Hz 120 VAC Operator...
Страница 55: ...INSTALLATION MANUAL APPENDIX 55 Wiring diagram Europe 50 Hz 220 VAC Operator...
Страница 56: ...56 APPENDIX INSTALLATION MANUAL...