INSTALLATION MANUAL
SAFETY
5
Converge or directly reflect sunlight on the
cover. This could cause permanent damage.
Wash the cover with harsh chemicals or
cleaners.
Use a pressure washer to clean any
component of the Covana cover. This could
result in premature wear or damage.
Use an extension cord to connect the Covana
cover to its power source. The cord may not
be properly grounded and the connection is a
shock hazard. An extension cord may cause a
voltage drop, which would cause the motor to
overheat.
CAUTION
Be sure to follow all the instructions in this
manual and only use the accessories and
tools approved by Covana.
Do not roll the Covana cover onto its side or
slide it on its side. This will damage the siding.
After removing a part, always place it in a safe
place on a clean and level surface to ensure
proper functionality.
For ground anchoring model
: Both posts of the
Covana cover must be properly anchored to
the foundation using the anchoring holes
located at the foot of each post.
For tub mount model
: Both posts of the
Covana cover must be properly anchored to
the hot tub frame using the tub mount
brackets and arms.
This product mainly contains steel, fiberglass,
foam, copper (Cu) and die-cast aluminum (Al).
The gearbox contains oil and other materials.
Please recycle them properly.
Both the up and down limit switches are pre-
adjusted at the factory. The down-limit switch
should never be readjusted. The up-limit
switch should be readjusted only to reduce the
maximum height of the cover to avoid possible
contact with its surroundings. Please refer to
the
Limit Switch Adjustment section
in this
manual before making any adjustments. An
improper adjustment can result in damage to
the drive system and/or cover.
Avoiding the risk of electrocution
ELECTRICAL DANGER
Failure to comply with these instructions may
result in death by electrocution or serious
injury. Disconnect or turn off and secure the
power supply before starting any intervention
on the Covana cover.
Always have a licensed electrical contractor
perform any electrical maintenance or repairs
on the Covana cover. The wiring must comply
with all the applicable local electrical codes
and regulations.
The Covana operator must be connected to a
circuit that is protected by a dedicated ground
fault circuit interrupter (GFCI) that complies
with all the applicable local electrical codes
and regulations.
Install the Covana cover in such a way that
drainage directs water away from the electrical
& base mechanical components.
Do not connect any auxiliary components to
the electrical system of the Covana cover
unless they have been approved by Covana.
Replace electrical components with original
components provided or approved by Covana.
Ask your dealer for replacement parts.
To reduce the risk of electrical shock, replace
a damaged cord immediately. Failure to do so
may result in death or serious personal injury
due to electrocution.
Do not bury the power cord. A buried cable
may result in death or serious personal injury
due to electrocution if direct burial-type cable
is not used, or if improper digging occurs.
ELECTRICAL WARNING
To reduce the risk of electric shock, the green-
colored terminal or the te
rminal marked “g,”
“gr,” “ground,” “grounding” or with a
⏚
symbol that is located inside the supply
terminal box or compartment must be
connected to the grounding means provided in
the electric supply service panel with a
continuous copper wire equivalent in size to
the
circuit
conductors
supplying
the
equipment.
Содержание C-HOR
Страница 1: ...Revision 13 2018 04 23...
Страница 53: ...INSTALLATION MANUAL APPENDIX 53 APPENDIX...
Страница 54: ...54 APPENDIX INSTALLATION MANUAL Wiring diagram North America 60 Hz 120 VAC Operator...
Страница 55: ...INSTALLATION MANUAL APPENDIX 55 Wiring diagram Europe 50 Hz 220 VAC Operator...
Страница 56: ...56 APPENDIX INSTALLATION MANUAL...