This appliance has been tested to and complies 
with the ANSIZ21.97 - 2010 and CGA CR97-003. 
The installation must conform to local codes or in 
the absence of local codes to the National Fuel 
Gas Code, ANSIZ223.1 and CAN/CGA-B149.2.

Keep the appliance area clear and free from 
combustible materials, gasoline, and other 

flammable vapors and liquids.

Solid Fuels should not be burned in this Gas 
Fireplace.  
Inspect the hose before each use of the appliance. 
The hose assembly must be replaced prior to the 
appliance being put into operation if there is 
evidence of excessive abrasion, wear, or if the 
hose is damaged. The replacement hose assembly
is specified in this manual. 
The burner must be inspected before each use. 
The burner must be replaced prior to the appliance 
being put into operation if it is evident that the 
burner is damaged. The replacement burner is 
specified in this manual. 

The burner should always be cleaned:

Disconnect it from the appliance, use a cleaner to 
remove blockages attached on the ports and drain 
the blockages from the gas inlet. A high pressured 
stream of water may also be used.

Do not use this appliance if any part has been 

under water. Immediately call a qualified service 

technician to inspect the appliance and to replace 
any part of the control system and any gas 
control which has been under water. 
This appliance is for outdoor use only in a 
well-ventilated space and should not be used in 
a building, garage, or any other enclosed area. 
other cylinders may be acceptable for use with the 
appliance provided they are compatible with the 
appliance retention means and accompanied by
illustration(s) depicting the cylinder mounted to the 
appliance utilizing the cylinder retention means and
the point of contact between the cylinder and the 
retention means.The cylinder should be 12 inches
in diameter and 18 inches high. The capacity is 
20lbs of propane. 

If the appliance is not in use, the gas must be turned 
off at the supply cylinder. 
Storage of an appliance indoors is permissible only 
if the cylinder is disconnected and removed from the 
appliance. 
Cylinders must be stored outdoors in a well-ventilated 
area out of children’s reach. 
Disconnected cylinders must have a dust cap 
secured at the end of the valve and can not be stored 
in a building, garage, or any other enclosed area. 
The pressure regulator and hose assembly supplied 
with this appliance must be used. Replacement 
pressure regulators and hose assemblies must be 
the ones specified in this manual. 

The cylinder supply system must be arranged for 
vapor withdrawal. 
The cylinder used must include a collar to protect 
the cylinder valve. 

The Procedure for Checking for Gas Leaks:

Never test for leaks with a flame. Prior to first use, at 
the beginning of each season, or every time your LP 
gas tank is changed, you must check for gas leaks.
Follow these three steps:

1.  Make a soap solution by mixing one part liquid 

    detergent and one part water.
2.  Make sure the burner is off and then turn gas on at 
    source. 
3.  Apply the soap solution to all gas connections, 
    especially to the inlet/manifold pressure tap on the 
    gas valve after reading the pressure. Bubbles will 
    appear in the soap solution if the gas connections 
    are not properly sealed. If you have a gas leak, 
    tighten gas connections, turn off the gas at the 
    source, disconnect the fuel line from your fireplace 
    and call 1-877-539-7436 for repair assistance.

WARNING

!

WARNING

!

WARNING

!

WARNING

!

The LP-gas supply cylinder to be used must be:

1. Constructed and marked in accordance with the 
    U.S. Department of Transportation (D.O.T.) 
    Specifications for LP-Gas Cylinders, or the 
    Standard for Cylinders, Spheres and Tubes for
    Transportation of Dangerous Goods; and 
    Commission, CAN/CSA-B339 as applicable;
2. Provided with a listed overfilling prevention device; 
    and;
3. Provided with a cylinder connection device 
    compatible with the connection for the appliance.

Содержание TCS46GL

Страница 1: ...g property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance...

Страница 2: ...r and 18 inches high The capacity is 20lbs of propane If the appliance is not in use the gas must be turned off at the supply cylinder Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance Cylinders must be stored outdoors in a well ventilated area out of children s reach Disconnected cylinders must have a dust cap secured at the end of ...

Страница 3: ...ed call the help line at 1 877 539 7436 before returning this item to the store LAVA ROCKS HEX KEY WRENCH 10MM HEX KEY WRENCH 4MM BOLT CAP NUT M6 NUT M6 WASHER d6 5 D10 1 6 WASHER d6 5 D13 1 0 WASHER d6 5 D13 1 0 HANDLE BOLT M6 14 BOLT M6 40 COVER FUEL SUPPLY HOSE TILE UPPER CONNECTOR LOWER CONNECTOR TANK FASTENER TANK SUPPORT ASSEMBLY TABLE TOP FRONT DOOR CROSS BRACE LEFT FRAME RIGHT FRAME REAR F...

Страница 4: ...5 in to the connector tab of the lower connector 9 See Figure 4 Note The wheels attached on the tank support assembly 7 should be facing towards the outside Step 3 Fasten the tank support assembly 7 to the front door 5 by using bolts 15 and washers 17 Insert the tank fastener 8 in to the tabs on the front door 5 and fasten them together by using washers 17 and nuts 20 See Figure 3 Step 2 Insert bo...

Страница 5: ... 11 on to the table top 6 See Figure 7 Note The igniter valve should be facing the front left side of the fire pit Note If any EVA foams on the table top 6 are missing there are extra EVA foams in the hardware kit See Illustration B Step 6 Place the table top 6 on to the frame assembly Fasten them together by using bolts 15 and washers 17 Completely tighten all of the bolts and cover them with bol...

Страница 6: ...hung from or near this appliance 4 Any guard or protective device removed for servicing the appliance must be replaced prior to use 5 Installation and repair should be done by a qualified person The appliance should be inspected before use and at least annually by a qualified service technician Frequent cleaning may be required It is imperative that the control compartment burners and circulating ...

Страница 7: ...ustible construction 2 feet from sides and 2 feet from rear WARNING Use of your fire pit causes carbon residue to build up on the lava rocks inhibiting the airflow and leading to a more yellow flame Stir up the lava rocks regularly to remove these deposits and maintain a blue flame LP GAS SAFETY INSTRUCTIONS This outdoor fire pit is not intended to be installed in or on recreational vehicles and o...

Страница 8: ...bly instructions FIGURE A Step A Loosen the fuel supply hose from the igniter valve See Figure A Step B To remove the fuel supply hose from the tank rotate counterclockwise See Figure B INSTRUCTIONS FOR REMOVING THE TANK counterclockwise Note You must make periodic checks to ensure that all connections are secured CARE INSTRUCTIONS Note Close the valve tightly before removing the tank ...

Отзывы: