Safety 2
Important Safety
Instructions
SAVE THESE INSTRUCTIONS - This manual
contains important instructions that should be
followed during installation, operation, and
maintenance of the product.
This is the
safety alert symbol. When you see this symbol
on your pump or in this manual, look for one
of the following signal words and be alert to the
potential for personal injury!
indicates a hazard which, if not
avoided, will result in death or serious injury.
indicates a hazard which, if not
avoided, could result in death or serious injury.
indicates a hazard which, if not
avoided, could result in minor or moderate injury.
NOTICE addresses practices not related to
personal injury.
Carefully read and follow all safety instructions
in this manual and on pump .
Keep safety labels in good condition. Replace
missing or damaged safety labels.
California Proposition 65 Warning
This product and related
accessories contain chemicals known to the
State of California to cause cancer, birth defects
or other reproductive harm.
Specifications
Power supply required .................................. 115V, 60 HZ.
Liquid Temp. Range ......................... 32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ............15 Amps
Motor Full Load: ..................................................5.5 Amps
Discharge:
Check Valve ................................1-1/4” slip / 1-1/2” slip
Hose .....................................................................1-1/4”
NOTICE Do not reduce size of discharge pipe or
hose below 1-1/4” diameter. If discharge is too
small, pump will overheat and fail prematurely.
NOTICE This unit is not designed as a waterfall
or fountain pump, or for applications involving
salt water or brine! Use with waterfalls,
fountains, salt water or brine will void warranty.
Pump water only with this pump.
Do not use where water recirculates.
Not designed for use as a swimming
pool drainer.
NOTICE Read this Owner’s Manual for
installation, operation, and safety information.
Performance
GPH (LPH) at Total feet (m) of lift
5’
(1 .5m)
10’
(3m)
15’
(4 .6m)
20’
(6 .1m)
No flow
at height
shown
below
Capacity Gallons(L)/Hour
3200
(12 113)
2700
(10 220)
2000
(7 571)
1200
(4 542)
24’
(7.3m)
1. Know the pump application, limitations, and
potential hazards.
2. Do not use in water with fish present. If any oil
leaks out of the motor it can kill fish.
3. Disconnect power before servicing.
4. Release all pressure within system before
servicing any component.
5. Drain all water from system before servicing.
6. Secure discharge line before starting pump.
An unsecured discharge line will whip,
possibly causing personal injury and/or
property damage.
7. Check hoses for weak or worn condition
before each use, making certain that all
connections are secure.
8. Periodically inspect sump, pump and system
components. Keep free of debris and foreign
objects. Perform routine maintenance
as required.
9. Provide means of pressure relief for pumps
whose discharge line can be shut-off
or obstructed.
Содержание CLRP50