29
Orifice
091
Convert Surface Burners
1.
If installed, remove the burner grates.
2.
Remove the burner grates, burner caps, and the burner base.
3.
Remove the natural gas orifices with a 9/32" (7 mm) nut driver.
4.
Replace the natural gas orifices with the correct LP gas orifices from the LP
conversion kits. LP gas orifices are stamped with a size. Refer to the
following chart for correct LP gas orifice ratings and sizes for proper
placement.
Orifice size
(091 - Denotes 0.91 mm)