background image

1 Terminal Blocks

PCA-8

3 Functions

PCA-10

3.1  Input Voltage Range  

 

PCA-10

3.2  Inrush Current Limiting  

 

PCA-10

3.3  Overcurrent Protection  

 

PCA-10

3.4  Overvoltage Protection  

 

PCA-10

3.5  Thermal Protection  

 

PCA-10

3.6  External output voltage adjustment  

 

PCA-10

3.7  Constant current set value external variables  

 

PCA-11

3.8  Remote ON/OFF  

 

PCA-11

3.9  Remote sensing  

 

PCA-11

3.10  Signal Output (LED / Alarm)  

 

PCA-12

3.11  Communication function  

 

PCA-12

4 Series/Parallel Operation

PCA-13

5 Assembling and Installation Method

PCA-14

4.1  Series Operation  

 

PCA-13

4.2  Parallel Operation/Master-slave Operation  

 

PCA-13

5.1  Installation Method  

 

PCA-14

5.2 Derating 

 

 

PCA-15

5.3   Life expectancy and Warranty  

 

PCA-15

6 Others

PCA-16

7 Options

PCA-17

6.1  Output Current Monitor  

 

PCA-16

6.2 Isolation 

 

 

PCA-16

6.3  Auxiliary Power (AUX)  

 

PCA-16

6.4  Variable Speed Fan  

 

PCA-16

6.5  Medical Isolation Grade  

 

PCA-16

7.1  Outline of Options  

 

PCA-17

2 Wiring Input / Output Pin

PCA-9

2.1  Wiring input pin  

 

PCA-9

2.2  Wiring output pin  

 

PCA-9

2.3  Output side attaching externally condenser  

 

PCA-9

2.4  Connection to pulse load  

 

PCA-9

AC-DC Power Supplies Enclosed Type

Instruction Manual

PCA-7

Содержание PCA600F

Страница 1: ...Inrush current protection circuit PCB Pattern Series Parallel operation availability Material Single sided Double sided Series operation Parallel operation PCA600F Active filter 15 400 7 3 250V 16A R...

Страница 2: ...5 Assembling and Installation Method PCA 14 4 1 Series Operation PCA 13 4 2 Parallel Operation Master slave Operation PCA 13 5 1 Installation Method PCA 14 5 2 Derating PCA 15 5 3 Life expectancy and...

Страница 3: ...G Each terminal of CN1 and CN2 are connected inside the power supply Table 1 2 Pin Configuration and Functions of CN3 Pin No Function Ground level 1 AUX Auxiliary output AUXG 2 AUXG Auxiliary output g...

Страница 4: ...ient temperature 50 to 70 should be not more than the calculated value by linear interpolation Point A Fig 2 1 Temperature measurement point A thin electric wire could heat up and affect the power sup...

Страница 5: ...al to logic to turn off output Note Please avoid applying a voltage exceeding the rated voltage to an output terminal Doing so may cause power supply to malfunction or fail If this is unavoidable for...

Страница 6: ...pecifications of remote ON OFF Connection method Fig 3 1 a Fig 3 1 b Fig 3 1 c SW Logic Output ON SW open 0 1mA max SW open 0 1mA max SW close 0 5V max Output OFF SW close 3mA min SW close 3mA min SW...

Страница 7: ...the power supply stops Open collector method Good Low 0 5V max at 5mA Bad High 50V 5mA max 100kW 0 1mF PG PGG Fig 3 4 Internal circuit of PG Please note the followings when you use the alarms PG sign...

Страница 8: ...peration Wiring method with series operation is shown in Fig 4 2 The MS and SGND must be connected with each other Please use option part H PA 14 for connecting between MS and SGND Please decide one p...

Страница 9: ...er 10 seconds or setting the voltage of RC2 terminal to logic to turn off output 5 Assembling and Installation Method 5 1 Installation Method To keep enough isolation between screws and internal compo...

Страница 10: ...ectancy Mount Average ambient temperature yearly Life expectancy 0 Io 50 50 Io 100 All mounting direction Ta 35C 8 years 6 years Ta 40C 7 years 5 years Ta 50C 6 years 4 years Life expectancy R t 90 of...

Страница 11: ...e a voltage a few times higher than the applied voltage When you test a unit for isolation between the input and output input and the terminal FG or between the output and the terminal FG short circui...

Страница 12: ...0VAC When ambient temperature is 40 or less point B is 70 or less When ambient temperature is 70 point B is 75 or less The ambient temperature 40 to 70 should be not more than the calculated value by...