background image

1 Terminal Blocks

¿ 

PCA600F

1 2 3

4 5

6 7 8

9

0

å

1

AC (L)   Input Terminals  85 - 264VAC 1

f

45 - 66Hz

2

AC (N)   (M4)

3

Frame ground (M4)

4

-Output

5

+Output

6

LED for fault condition detection (ALARM)

7

LED for output voltage confirmation (DC_OK)

8

Output voltage adjustable potentiometer

9

CN1

9

CN2

0

CN3   Connectors

9

CN4

*

  Please refer to optional parts for the exclusive harness.

1

2

1

2

1

2

CN1

CN3

CN2

CN4

1

2

12

11

10

9

11

12

7

8

Fig.1.1  Connector pin numbers

Table 1.1  Pin Configuration and Functions of CN1, CN2

Pin No.

Function

Ground 

level

1

+S

+Remote sensing

COM

2

N.C.

No connection

-

3

N.C.

No connection

-

4

-S

-Remote sensing

COM

5

VTRM

Adjustment of output voltage

COM

6

COM

Common ground (for signal)

COM

7

INFO

Extended UART signal

SGND

8

CM

Current Monitor

COM

9

MS

Master Slave signal

SGND

10

SGND

Signal ground

SGND

11

RC2

Remote ON/OFF

RCG

12

RCG

Remote ON/OFF ground

RCG

*

  Each terminal of CN1 and CN2 are connected inside the power supply.

Table 1.2  Pin Configuration and Functions of CN3

Pin No.

Function

Ground 

level

1

AUX

Auxiliary output

AUXG

2

AUXG

Auxiliary output ground

AUXG

3

RC1

Remote ON/OFF

AUXG

4

AUXG

Auxiliary output ground

AUXG

5

PG

Alarm

PGG

6

PGG

Alarm ground

PGG

7

ITRM

Adjustment of output current

COM

8

COM

Common ground (for signal)

COM

9

VTRM_EN Enable Vtrm

COM

10

SLV_EN

Enable Slave mode

COM

Table 1.3  Pin Configuration and Functions of CN4

Pin No.

Function

Ground 

level

1

N.C.

No connection

-

2

SGND

Signal ground

SGND

3

N.C.

No connection

-

4

N.C.

No connection

-

5

ADDR0

Address bit 0

SGND

6

ADDR1

Address bit 1

SGND

7

ADDR2

Address bit 2

SGND

8

SGND

Signal ground

SGND

Table 1.4  Matching connectors and terminals

Connector

Housing

Terminal

Mfr.

CN1 S12B-PHDSS PHDR-12VS Reel :  SPHD-002T-P0.5

Loose  : BPHD-001T-P0.5 

*

1

 BPHD-002T-P0.5 

*

1

J.S.T

CN2

CN3 S10B-PHDSS

PHDR-10VS

CN4 S8B-PHDSS

PHDR-8VS

*

1  The manufacturer prepares only the ratchet hand.

AC-DC Power Supplies Enclosed Type

Instruction Manual

PCA-8

Содержание PCA600F

Страница 1: ...Inrush current protection circuit PCB Pattern Series Parallel operation availability Material Single sided Double sided Series operation Parallel operation PCA600F Active filter 15 400 7 3 250V 16A R...

Страница 2: ...5 Assembling and Installation Method PCA 14 4 1 Series Operation PCA 13 4 2 Parallel Operation Master slave Operation PCA 13 5 1 Installation Method PCA 14 5 2 Derating PCA 15 5 3 Life expectancy and...

Страница 3: ...G Each terminal of CN1 and CN2 are connected inside the power supply Table 1 2 Pin Configuration and Functions of CN3 Pin No Function Ground level 1 AUX Auxiliary output AUXG 2 AUXG Auxiliary output g...

Страница 4: ...ient temperature 50 to 70 should be not more than the calculated value by linear interpolation Point A Fig 2 1 Temperature measurement point A thin electric wire could heat up and affect the power sup...

Страница 5: ...al to logic to turn off output Note Please avoid applying a voltage exceeding the rated voltage to an output terminal Doing so may cause power supply to malfunction or fail If this is unavoidable for...

Страница 6: ...pecifications of remote ON OFF Connection method Fig 3 1 a Fig 3 1 b Fig 3 1 c SW Logic Output ON SW open 0 1mA max SW open 0 1mA max SW close 0 5V max Output OFF SW close 3mA min SW close 3mA min SW...

Страница 7: ...the power supply stops Open collector method Good Low 0 5V max at 5mA Bad High 50V 5mA max 100kW 0 1mF PG PGG Fig 3 4 Internal circuit of PG Please note the followings when you use the alarms PG sign...

Страница 8: ...peration Wiring method with series operation is shown in Fig 4 2 The MS and SGND must be connected with each other Please use option part H PA 14 for connecting between MS and SGND Please decide one p...

Страница 9: ...er 10 seconds or setting the voltage of RC2 terminal to logic to turn off output 5 Assembling and Installation Method 5 1 Installation Method To keep enough isolation between screws and internal compo...

Страница 10: ...ectancy Mount Average ambient temperature yearly Life expectancy 0 Io 50 50 Io 100 All mounting direction Ta 35C 8 years 6 years Ta 40C 7 years 5 years Ta 50C 6 years 4 years Life expectancy R t 90 of...

Страница 11: ...e a voltage a few times higher than the applied voltage When you test a unit for isolation between the input and output input and the terminal FG or between the output and the terminal FG short circui...

Страница 12: ...0VAC When ambient temperature is 40 or less point B is 70 or less When ambient temperature is 70 point B is 75 or less The ambient temperature 40 to 70 should be not more than the calculated value by...

Отзывы: