7 Options
7.1 Outline of Options
*
Please inquire us for details of specifications and delivery timing.
¿
-TP2
¡
Option -T units have a terminal block in stead of an output bus bar.
¡
For PCA600F, this option is available in -12V, -15V and -24V types.
¡
When wiring the load wire, select the wire in consideration of the
heat generation so that the temperature of points A in Fig. 7.2 will
be below the specified temperature.
Please note that if the wire is thin, the wiring heats up, heat is
transferred to the inside of the power supply, and the power sup-
ply may break down.
Please use within the item number 5.2 derating characteristics.
Input condition: Vin=85 to 170VAC
-
When ambient temperature is 40
ª
or less, point B is 70
ª
or less
-
When ambient temperature is 70
ª
, point B is 75
ª
or less
( The ambient temperature 40
ª
to 70
ª
should be not more than
the calculated value by linear interpolation)
Input condition: Vin=170 to 264VAC
-
When ambient temperature is 50
ª
or less, point B is 85
ª
or less
-
When ambient temperature is 70
ª
, point B is 75
ª
or less
( The ambient temperature 50
ª
to 70
ª
should be not more than
the calculated value by linear interpolation)
Please pay attention to electric shock and leakage during mea-
surement. Temperature formulation place is conductive part.
1 2 3
4
5
Fig.7.1 TP2 specification example (PCA600F)
1
AC (L) Input Terminals 85 - 264VAC 1
f
45 - 66Hz
2
AC (N) (M4)
3
Frame ground (M4)
4
-Output (M5)
5
+Output (M5)
Point B
Fig.7.2 Temperature measurement point
AC-DC Power Supplies Enclosed Type
Instruction Manual
PCA-17