7  Options

7.1 Outline of Options

*

 Please inquire us for details of specifications and delivery timing.

¿ 

-TP2

¡

Option -T units have a terminal block in stead of an output bus bar.

¡

For PCA600F, this option is available in -12V, -15V and -24V types.

¡

When wiring the load wire, select the wire in consideration of the 
heat generation so that the temperature of points A in Fig. 7.2 will 
be below the specified temperature.

  Please note that if the wire is thin, the wiring heats up, heat is 

transferred to the inside of the power supply, and the power sup-
ply may break down.

  Please use within the item number 5.2 derating characteristics.

  Input condition: Vin=85 to 170VAC
 

-

 When ambient temperature is 40

ª

 or less, point B is 70

ª

 or less

 

-

 When ambient temperature is 70

ª

, point B is 75

ª

 or less

   ( The ambient temperature 40

ª

 to 70

ª

 should be not more than 

the calculated value by linear interpolation)

  Input condition: Vin=170 to 264VAC
 

-

 When ambient temperature is 50

ª

 or less, point B is 85

ª

 or less

 

-

 When ambient temperature is 70

ª

, point B is 75

ª

 or less

   ( The ambient temperature 50

ª

 to 70

ª

 should be not more than 

the calculated value by linear interpolation)

  Please pay attention to electric shock and leakage during mea-

surement. Temperature formulation place is conductive part.

1 2 3

4

5

Fig.7.1  TP2 specification example (PCA600F)

1

AC (L)   Input Terminals  85 - 264VAC 1

f

45 - 66Hz

2

AC (N)   (M4)

3

Frame ground (M4)

4

-Output (M5)

5

+Output (M5)

Point B

Fig.7.2  Temperature measurement point

AC-DC Power Supplies Enclosed Type

Instruction Manual

PCA-17

Содержание PCA600F

Страница 1: ...Inrush current protection circuit PCB Pattern Series Parallel operation availability Material Single sided Double sided Series operation Parallel operation PCA600F Active filter 15 400 7 3 250V 16A R...

Страница 2: ...5 Assembling and Installation Method PCA 14 4 1 Series Operation PCA 13 4 2 Parallel Operation Master slave Operation PCA 13 5 1 Installation Method PCA 14 5 2 Derating PCA 15 5 3 Life expectancy and...

Страница 3: ...G Each terminal of CN1 and CN2 are connected inside the power supply Table 1 2 Pin Configuration and Functions of CN3 Pin No Function Ground level 1 AUX Auxiliary output AUXG 2 AUXG Auxiliary output g...

Страница 4: ...ient temperature 50 to 70 should be not more than the calculated value by linear interpolation Point A Fig 2 1 Temperature measurement point A thin electric wire could heat up and affect the power sup...

Страница 5: ...al to logic to turn off output Note Please avoid applying a voltage exceeding the rated voltage to an output terminal Doing so may cause power supply to malfunction or fail If this is unavoidable for...

Страница 6: ...pecifications of remote ON OFF Connection method Fig 3 1 a Fig 3 1 b Fig 3 1 c SW Logic Output ON SW open 0 1mA max SW open 0 1mA max SW close 0 5V max Output OFF SW close 3mA min SW close 3mA min SW...

Страница 7: ...the power supply stops Open collector method Good Low 0 5V max at 5mA Bad High 50V 5mA max 100kW 0 1mF PG PGG Fig 3 4 Internal circuit of PG Please note the followings when you use the alarms PG sign...

Страница 8: ...peration Wiring method with series operation is shown in Fig 4 2 The MS and SGND must be connected with each other Please use option part H PA 14 for connecting between MS and SGND Please decide one p...

Страница 9: ...er 10 seconds or setting the voltage of RC2 terminal to logic to turn off output 5 Assembling and Installation Method 5 1 Installation Method To keep enough isolation between screws and internal compo...

Страница 10: ...ectancy Mount Average ambient temperature yearly Life expectancy 0 Io 50 50 Io 100 All mounting direction Ta 35C 8 years 6 years Ta 40C 7 years 5 years Ta 50C 6 years 4 years Life expectancy R t 90 of...

Страница 11: ...e a voltage a few times higher than the applied voltage When you test a unit for isolation between the input and output input and the terminal FG or between the output and the terminal FG short circui...

Страница 12: ...0VAC When ambient temperature is 40 or less point B is 70 or less When ambient temperature is 70 point B is 75 or less The ambient temperature 40 to 70 should be not more than the calculated value by...

Отзывы: