Skärmbild Förklaring
ALARM 1
The dehumidifier’s automatic overheating protection has temporarily stopped the
system. The dehumidifier restarts as soon as the temperature has sunk but to
prevent this from happening again it should be attended to in accordance with its
manual. A likely cause of the incident is, as the text says, that the filter is clogged
and needs to be replaced. When the corrective measures have been taken,
confirm them by pushing <OK>. The alarm will then disappear and a log post is
created.
If the problems remain after these measures, please contact your retailer.
LARM 2
Like the text says, the dehumidifier has failed and needs to be repaired by
professional service technician. The dehumidifier does no longer function. Please
contact your retailer as soon as possible.
LARM 3
The relative humidity is, or has temporarily been, above the alarm level. As a first
measure, verify that the alarm level setting is relevant, that the humidity is indeed
a problem. Thereafter, use the dehumidifier manual to locate the error. Confirm
corrective actions performed by pushing <OK>. The alarm will then disappear and
a log post is created.
LARM 4
Like the text says, the Control Unit has failed and needs to be repaired by
professional service technician. The dehumidifier and its built-in fan are now
running continuously to prevent damage on the property. As continuous
dehumidification means significantly higher energy consumption, please contact
your retailer as soon as possible.
LARM 5
This alarm is activated when the Control Panel has not heard radio traffic from the
Control Unit for sixty minutes. If the connection is reestablished, the alarm
disappears automatically.
As a first measure, verify that the dehumidifier is powered so that power loss is not
the reason for the alarm. If the problem remains, restart the dehumidifier by
disconnecting and then reconnecting power and pair the Control Panel again
according to the installation procedure of this manual.
If the problem still remains, contact your retailer.
SERVICE
The system presents this service reminder once every year. Follow the instructions
in the dehumidifier manual.
When the service is confirmed by pushing <OK>, the built-in timer is automatically
reset and the reminder will not reappear until after one year. A log post is created
and stored.
LOGGNINGS-
VARNING
This screen is presented if there is a problem with the logging to the USB stick. The
problem can that there is no memory available or that the USB stick itself has
failed. To isolate the problem, if possible, please try another USB stick formatted to
FAT32 to see if that eliminates the issue. If not possible or if the problem remains,
please contact your retailer.