HomeVision® Pro/Lite
© Corroventa Avfuktning AB
Rev A
16 (30)
”Remove USB stick”
prepares the Control Panel for
removal of the USB stick by temporarily stopping the
logging process, preventing the files from being
corrupted. Always use this function when removing
the USB.
Note: The Pro version stores a user readable log file in
CSV (comma separated) format on the USB stick. The
file can be analyzed and studied with for instance
Microsoft Excel. Always make a copy of the log file to a
different location and then use that file, not the
original in order to prevent the file from being
corrupted. Put the USB-stick back in the Control Panel
as soon as the copy is made in order not to lose any log
data.
”Select language”
allows for the user to select Control
Panel language.
Mode and reset menu
Accessed from the default view by pushing <Setup>
and then down arrow.
To change parameters, push <Change>, use down
arrow to select parameter to change and push
<Select>.
Select parameter value of choice using the arrows and
then push <Save>.
”Continuous ventilation”
determines whether the fan
shall operate continuously or only when the
dehumidifier is active. Normally it is recommended to
have continuous ventilation, particularly if there are
problems with radon or bad smell from the crawl
space. If no such problems exist, deactivation of
continuous fan can be considered in order to save
energy.
”RH Control Mode”
allows for selection of either Fixed
control with setpoint RH% or Mould Growth Index
control allowing the maximum relative humidity vary
with the temperature. Both these modes and
principles are explained in previous chapters of this
manual.
”Reset service indicator”
allows for reset of the built-in
service timer that provides a yearly service reminder.
Normally this function is never used as the reset is
automatic when performed service is acknowledged
through the service reminder screen.