HomeVision® Pro/Lite
© Corroventa Avfuktning AB
Rev A
13 (30)
2.
Connect the Control Unit cable to the dehumidifier.
3.
Provided that the dehumidifier installation is completed, connect its power cable. Take the
Control Panel and:
a)
In the default view,push <Setup>.
b)
When the Adminstration view to the right is
presented, push <Change>.
c)
Push down arrow and verify that the “Connect
new unit ” alternative “Standard” is selected.
d)
Push <Select> and when ”Standard” is visible,
push <Save>.
The display now shows the text ”Attempting to pair up…” and as soon as connection is
established “Pairing successful” is presented which is acknowledged by pushing <OK>.
The Control Panel returns to the default view where status indications, temperature and
relative humidity are presented. It may take up to 45 seconds before current status and
values are presented.
In the default view there is also an indication of the radio signal quality. The indication is
based on how many data packages are received at their first transmission why the
quality normally builds up over time. It always shows level one in the beginning and is
therefore not to be compared with the signal strength indication of a cellular phone.
Note:
When the Control Unit is powered, it is open to pairing for two minutes only.
Therefore,as a first measure when failing to pair the system, restart the Control Unit and
try again.
Installation of Control Panel
When the Control Unit is installed and radio connection between that and the Control Panel is
established, proceed as follows:
1.
Select position for the Control Panel where there is power outlet within reach of the power
adaptor cable and preferably where any alarm would be noticed as soon as possible (the
screen back light starts to flash when alarms are presented). Furthermore, if there are small
children in the household, the Control Panel should be placed beyond their reach.
Put the Control Panel at the intended position and leave it there for a couple of minutes to
let the signal quality indication reflect current conditions. Verify that at the indication is at
level two or higher.
2.
Detach the wall bracket from the Control Panel by pushing it downwards. Hold the bracket to
the wall at the intended position and mark the position of the three holes to be drilled. Drill
the holes and insert the wall plugs. Fix the bracket to the wall using the three screws.