2.
On the A4ES or the A4ESX, reach into the
machine between the fan and the rotor
assembly and pull the internal wet air hose
off the spigot.
Pull the entire rotor assembly upwards to lift
it out of the machine. Be careful not to
damage the rotor.
On the A2ES, it is easier to remove the fan
gable. Remove the two screws that hold the
fan gable in place, found between the feet of
the machine.
When the screws are remove, pull the fan
gable upwards and remove it.
3.
On the rotor assembly, push the tensioning
wheel back and slide the belt off the wheel so
that the rotor can be turned freely.
4.
Note: Always use a suitable protective mask
and clean the rotor at suitable location
outdoors.
With pressurized air, carefully blow the rotor
interior clean. Hold the nozzle approximately
15cm from the rotor and begin by blowing
from the heater cover side of the rotor. This
way, the air will flow through the rotor in the
opposite direction of what it usually does
which will prevent further dirt from getting
stuck inside.
When later cleaning from the other side,
avoid blowing into the heater cover as the
dirt will collect inside. Only blow on the rotor
where the opposite side is free and
unobstructed.
5.
When the rotor is cleaned, assemble the
dehumidifier in the reverse order, thus:
•
Mount the belt
•
Carefully lower the rotor assembly
into the machine.
Содержание A2 ES
Страница 1: ...A2 ES A4 ES A4 ESX ADSORPTION DEHUMIDIFIERS USER MANUAL...
Страница 39: ...Interface Map for CTR A2ES CTR A4 ES and CTR A ES Top Menu...
Страница 40: ...Sublevels Info Statistics Info Reset Info Info Info Info Info...
Страница 42: ...Create Activate Edit Edit Change...
Страница 43: ...Info Change OK Info Info...
Страница 44: ...Info Change OK...