background image

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021 | Page 3

FCC Statements

Safety Precautions

Corning strongly recommends reviewing and adhering to the following cautions and 

notices before installing and operating the SCRN-530. 

Caution: 

Any changes or modifications to this device not explicitly approved by 

manufacturer could void your authority to operate this equipment.

RF Exposure Warning Statement: 

This equipment complies with FCC radiation 

exposure limits set forth for an uncontrolled environment. This equipment should be 

installed and operated with minimum 4

0

 cm between the radiator and your body. This 

transmitter must not be collocated or operating in conjunction with any other antenna or 

transmitter unless authorized to do so by the FCC.
This device can be expected to comply with part 15 of the FCC Rules provided it is 

assembled in exact accordance with the instructions provided with this kit. Operation is 

subject to the following conditions: (1) This device may not cause harmful interference, 

and (2) this device must accept any interference received including interference that may 

cause undesired operation.

NOTE: 

This equipment has been tested and found to comply with the limits for a Class A 

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when the equipment is operated in a 

commercial environment. This equipment generates, uses, and can radiate radio 

frequency energy and, if not installed and used in accordance with the instruction 

manual, may cause harmful interference to radio communications. Operation of this 

equipment in a residential area is likely to cause harmful interference in which case the 

user will be required to correct the interference at his own expense.

WARNING: 

This warning symbolizes danger that may cause severe injury or death. Before installing or 

servicing equipment ensure that you are aware of all hazards involved with electrical circuitry and become 

familiar with applicable safety standards and national and local electrical codes and any other relevant 

standards.

WARNING:

 For Professionals & Trained Installers:

• The device is designed for wall mount or ceiling mount applications only in an enterprise environment.

• Installers are required to maintain RF safety distances of 40 cm during the course of installation process.

• Wall installation should be avoided, if a minimum safety distance of 40 cm cannot be maintained. 

WARNING: 

All electrical equipment must be properly grounded. Refer to national and local electrical codes 

and any other relevant standards for electrical grounding information.

Содержание SCRN-530

Страница 1: ...1 Small Cell Radio Node SCRN 530 Hardware Installation Guide DOC SCRN 530 HIG Issue 1 Related Literature Search www Corning com opcomm Click Required Resources Table 1 Revision History Issue Date Summ...

Страница 2: ...Micro USB Port 8 5 4 Status LED 8 Section 6 System Specifications 9 Section 7 Compliance 10 Section 8 Mounting the SCRN 530 11 8 1 Installing the SCRN 530 on a Ceiling 11 8 2 Installing the SCRN 530 o...

Страница 3: ...A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment...

Страница 4: ...nd internal components Ensure that the SCRN 530 and associated antenna equipment is installed and serviced according to national and local ESD standards CAUTION Do not open the SCRN 530 casing E RAN w...

Страница 5: ...aration powering and experience in hardware installation and maintenance 2 Product Overview The SCRN 530 is a 5G mmWave Time Division Duplexing TDD radio node that supports 2 x 2 MIMO small cell opera...

Страница 6: ...dio Node Model Table 1 includes the SCRN 530 model configuration Table 1 Radio Node Configuration Radio Node Model Description Antenna Type SCRN 530 39 39 GHz band n260 mmWave RN with 8 x 8 dual polar...

Страница 7: ...30 Hardware Installation Guide DOC SCRN 530 HIG 21 July 2021 Page 7 4 SCRN 530 Views Figure 2 and Figure 3 display views of the SCRN 530 Figure 2 SCRN 530 Cover Figure 3 SCRN 530 With Ceiling Mount Br...

Страница 8: ...work interface module The hot pluggable SFP supplied with this SCRN 530 must be installed in the Transceiver Port The LC connector terminated end of the fiber pair of an ActiFi cable or other approved...

Страница 9: ...pport per UE Dimensions 279 4 x 279 4 x 80 3 mm 11 0 x 11 0 x 3 16 in Weight 4 5 kg 9 9 lbs Input Power 1 x 48 VDC Phoenix deliverable using Corning ActiFi 2 fiber 2 copper conductor composite cable P...

Страница 10: ...ed Unit X 509 certificate based authentication Environmental Requirements Operating temperature range 0 to 45 C 32 to 113 F Non operating temperature range 40 to 70 C 40 to 158 F Relative humidity Ope...

Страница 11: ...izes RF leakage outside the building When mounting near a wall or other obstruction orient the mounting bracket so that the top of the radio node faces towards the coverage area and faces away from th...

Страница 12: ...ted but if they do loosen them slightly to be able to slide the ceiling mount bracket on and off Step 3 Secure the ceiling tethering system Make sure that it can support the weight of the radio node a...

Страница 13: ...ing Mount Bracket 8 2 Installing the SCRN 530 on a Wall The SCRN 530 comes with the ceiling mount bracket attached and has the multi angle wall mount bracket loose in the box Figure 8 shows the radio...

Страница 14: ...rit level use the wall mount bracket as a template to mark securing hole locations Step 2 If required install sheet rock plugs Step 3 Attach the wall mount bracket to the wall Figure 8 shows the radio...

Страница 15: ...Cabling Guidelines Incorrectly cabling the SCRN 530 can result in crushed cables and loss of communications to the radio node Follow these guidelines when cabling the SCRN 530 Make sure that the cabl...

Страница 16: ...e brackets and cable connectors Step 4 Loosen the captive securing screw and slide out the bracket from the radio node 12 SCRN 530 LED Boot Sequence The radio node state machine is sequential and prog...

Страница 17: ...state should be very short lived and should transition to the next state immediately A radio node should not stay in this state indefinitely Note Flashing Green is also used to indicate a radio node t...

Страница 18: ...k firewall between radio node and centralized unit 5 Operating System Booting SolidGreen for a few seconds off for about 30 seconds then Solid Green The radio node loads the operating system and start...

Страница 19: ...ode Standard command to re enable the LED display set System RadioNode LED DefaultMode Standard Step 2 Issue the show System RadioNode LED command to verify the configuration show System RadioNode LED...

Страница 20: ...attended Corning Small Cell training in the past two years Email onesupport corning com to request a login if you meet these criteria Corning Optical Communications LLC 4200 Corning Place Charlotte NC...

Отзывы: