![CORNING SCF-6 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/corning/scf-6/scf-6_manual_2668593020.webp)
SCF-6 Canister and Inline Splice Closures
Page 20
SRP 003-485 • Issue 6 • October 2006
Refer to SRP 206-286 (Mechanical End Cap Canister Closure Sealing Checklist) to ensure all
critical
steps in Sections 5.4 and 5.7 for sealing the closure have been performed accurately.
Figure 23 — Sealing Grommet Size
Table 2 — Cable Diameter
Figure 24 — Washer Orientation
Step 3
Place the end cap gauge to determine which size sealing grommet is required
(Figure 23 and Table 2).
Step 4
Place a toothed washer onto the
sealing grommet and insert
both into the opened port from
the strain-relief side of the end
cap (Figure 24). Verify correct
placement of toothed washer on
grommet.
Figure 25 — Lock Nut
Figure 26 — Compression Screw
Sealing Grommet
Toothed Washer
KPA-0468
5.7
Install Drop Port Cable into End Cap
Step 1
Secure the sealing grommet and
toothed washer with the lock
nut on the inside of the end cap.
Step 2
Use the end cap gauge to
tighten the nut until it stops and
is tight (Figure 25).
Step 3
Slide the compression screw
over the cable.
Step 4
Slide the cable through the port
(Figure 26).
A
A
KPA-0469
KPA-0470
Cable
Cable
D
Cable
Cable
D
KPA-0508
Greater than
or equal to:
Less than:
18 mm
AND
Large
AND
Medium
AND
Small
5 mm
NOTE: Dimensions are for reference only.
Use SCF6 combination wrench to determine cable size.
Cable
Diameter
Range:
If Cable Diameter Is:
Cable is too small for sealing system.
Select
Grommet
Size
Wrench Gauge
"D"
Wrench Gauge
"E"
Wrench Gauge
"K"
Less than "K"
Wrench Gauge
"F"
Wrench Gauge
"D"
Wrench Gauge
"E"
Flat
Requires p/n SCF-KT-G84-F Grommet kit
(purchased separately)
KPA-0509